Determination of cable parameters in skeletal muscle fibres during repetitive firing of action potentials

机译:重复发射动作电位期间骨骼肌纤维中电缆参数的确定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Recent studies in rat muscle fibres show that repetitive firing of action potentials causes changes in fibre resting membrane conductance (Gm) that reflect regulation of ClC-1 Cl and KATP K+ ion channels. Methodologically, these findings were obtained by inserting two microelectrodes at close proximity in the same fibres enabling measurements of fibre input resistance (Rin) in between action potential trains. Since the fibre length constant (λ) could not be determined, however, the calculation of Gm relied on the assumptions that the specific cytosolic resistivity (Ri) and muscle fibre volume remained constant during the repeated action potential firing. Here we present a three-microelectrode technique that enables determinations of multiple cable parameters in action potential-firing fibres including Rin and λ as well as waveform and conduction velocities of fully propagating action potentials. It is shown that in both rat and mouse extensor digitorum longus (EDL) fibres, action potential firing leads to substantial changes in both muscle fibre volume and Ri. The analysis also showed, however, that regardless of these changes, rat and mouse EDL fibres both exhibited initial decreases in Gm that were eventually followed by a ∼3-fold, fully reversible increase in Gm after the firing of 1450–1800 action potentials. Using this three-electrode method we further show that the latter rise in Gm was closely associated with excitation failures and loss of action potential signal above −20 mV.
机译:最近对大鼠肌肉纤维的研究表明,动作电位的反复发射会引起纤维静息膜电导(Gm)的变化,从而反映ClC-1 Cl -和KATP K + 的调节离子通道。从方法上讲,这些发现是通过在同一根光纤中紧密相邻地插入两个微电极而实现的,从而可以测量动作电位序列之间的光纤输入电阻(Rin)。但是,由于无法确定纤维长度常数(λ),因此Gm的计算依赖于这样的假设,即在重复动作电位触发过程中,胞浆电阻率(Ri)和肌纤维体积保持恒定。在这里,我们介绍一种三电极技术,该技术能够确定动作电位发射光纤中的多个电缆参数,包括Rin和λ以及完全传播的动作电位的波形和传导速度。结果表明,在大鼠和小鼠趾长伸肌(EDL)纤维中,动作电位触发都会导致肌纤维体积和Ri的实质性变化。然而,分析还表明,不管这些变化如何,大鼠和小鼠的EDL纤维均显示出最初的Gm降​​低,最终在激发1450–1800动作电位后,Gm约3倍完全可逆地增加。使用这种三电极方法,我们进一步表明,后者的Gm升高与励磁失败和-20 mV以上的动作电位信号损失密切相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号