>Aims: To evaluate performance of frequency doubling technology (FDT) perimetry using the Humphrey Matrix 24-2 thresholding program in a hospital eye service (HES) glaucoma clinic.>Methods: A random sample of individuals referred consecutively to the HES for suspected glaucoma were examined with 24-2 threshold FDT in addition to routine clinical tests. The discriminatory power of FDT and standard automated perimetry (SAP) were assessed using glaucomatous optic nerve head appearance as the reference gold standard.>Results: 48 of 62 eligible referred individuals were recruited. Glaucoma prevalence was 31%. Median test duration per eye was 5 minutes 16 seconds for FDT and 5 minutes 9 seconds for SAP. There was no significant difference (p = 0.184) between proportions of individuals with reliable test results (FDT 75%, SAP 63%). Using a clinically appropriate binary criterion for abnormal visual field, sensitivity and specificity levels were 100% and 26% respectively for FDT and 80% and 52% for SAP. Both tests had higher negative than positive predictive values with marginal differences between tests. Criterion free receiver operator characteristic analysis revealed minimal discriminatory power differences.>Conclusions: In a HES glaucoma clinic in which new referrals are evaluated, threshold 24-2 FDT testing with the Humphrey Matrix has performance characteristics similar to SAP. These findings suggest threshold testing using the FDT Matrix and SAP is comparable when the 24-2 test pattern is used.
机译:>目标:在医院眼科服务(HES)青光眼诊所中使用Humphrey Matrix 24-2阈值程序评估倍频技术(FDT)视野检查的性能。>方法:除常规临床检查外,还采用24-2阈值FDT对连续转诊至HES的可疑青光眼患者的随机样本进行了检查。以青光眼性视神经乳头外观为参考金标准,评估了FDT和标准自动视野检查(SAP)的鉴别力。>结果:招募了62名合格的被推荐人中的48名。青光眼的患病率为31%。对于FDT,每只眼睛的平均测试持续时间为5分16秒,对于SAP为5分9秒。具有可靠测试结果(FDT 75%,SAP 63%)的个体比例之间没有显着差异(p = 0.184)。使用适用于异常视野的临床适当二进制标准,FDT的敏感性和特异性水平分别为100%和26%,SAP的敏感性和特异性水平分别为80%和52%。两种测试的阴性预测值均高于阳性预测值,且测试之间存在边际差异。无标准的接收器操作员特征分析显示出最小的区分能力差异。>结论:在评估新推荐人的HES青光眼诊所中,使用汉弗莱矩阵进行的24-2 FDT阈值测试具有与SAP相似的性能特征。这些发现表明,当使用24-2测试模式时,使用FDT Matrix和SAP进行阈值测试是相当的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号