首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study
【2h】

Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study

机译:术前评估位置诱发性旋扭的应用:一项视频眼科研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: Positionally induced cyclotorsion could be an important factor concerning correction of astigmatism in refractive surgery. The method of binocular three dimensional infrared video-oculography (3D-VOG) was used to determine a possible influence of body position on cyclotorsion.>Methods: 38 eyes (19 healthy subjects, median value of age 25.5) with normal binocular vision were examined using 3D-VOG. This method records ocular motions and positions of both eyes simultaneously in the x, y, and z axis. Cycloposition of the eyes was recorded first in a seated position (both eyes open, test 1), then in a supine position (right eye closed, test 2), occlusion of both eyes (test 3), both eyes open (test 4). Cyclovergence was calculated as the difference between the right and the left eye positions.>Results: The range of cyclotorsion of the right and left eye in all four tests was between 1.13° excyclotorsion and 0.34° incyclotorsion. There was no statistically significant difference of the median values for torsion for the four test situations. Concerning the influence of body position on cyclotorsion, a statistically significant difference between the different test positions and settings did not exist. Median values for right/left torsion/cyclovergence were: 0.17/0.04/0.02 (test 1), −0.31/−0.71/−0.16 (test 2), −1.09/−0.60/0.82 (test 3), 0.28/0.28/−0.82 (test 4).>Conclusions: Cyclotorsion does not significantly change between seated and supine position in subjects with normal binocular vision and stable fixation. In these subjects, an erroneous refractive surgery due to incorrect measurement of the axis of astigmatism in the seated position and performing the refractive surgery in the supine position, is very unlikely.
机译:>目的:位置诱发的旋扭可能是矫正屈光手术中散光的重要因素。使用双眼三维红外眼动摄影法(3D-VOG)确定身体位置对环扭的可能影响。>方法::38眼(19名健康受试者,中位年龄25.5岁)双眼视觉正常的患者使用3D-VOG检查。此方法同时记录x,y和z轴的眼动和两只眼睛的位置。首先在坐姿(双眼张开,测试1)中记录眼睛的眼位,然后在仰卧位(右眼闭合,测试2),闭塞双眼(测试3),双眼张开(测试4)。 。计算出旋回度,作为左右眼位置之间的差异。>结果:在所有四个测试中,右眼和左眼的回旋范围在1.13°内旋和0.34°内旋之间。在这四种测试情况下,扭转中位数没有统计学上的显着差异。关于体位对旋扭的影响,不同的测试位置和设置之间不存在统计学上的显着差异。右/左扭转/环过盈的中值是:0.17 / 0.04 / 0.02(测试1),-0.31 / -0.71 / -0.16(测试2),-1.09 / -0.60 / 0.82(测试3),0.28 / 0.28 / −0.82(测试4)。>结论:双眼视力正常且固定稳定的受试者,在坐位和仰卧位之间,旋扭没有明显改变。在这些受试者中,极不可能发生因坐位位置的散光轴测量不正确而仰卧位置进行屈光手术而导致的错误屈光手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号