首页> 美国卫生研究院文献>The British Journal of Ophthalmology >The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: the Blue Mountains Eye Study
【2h】

The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: the Blue Mountains Eye Study

机译:视盘直径对以人群为基础的队列中垂直杯对盘比率的百分位数的影响:蓝山眼研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective: The 97.5th percentile for vertical cup to disc ratio (VCDR) has been proposed as a useful tool to assist in the diagnosis of glaucoma in population studies. Previous reports of VCDR percentiles have either not been adjusted for disc size or have been calculated by regression analysis from small hospital based cohorts. The authors’ aim was to generate VCDR percentiles in a large, population based sample. >Methods: Data were collected from 3654 individuals, aged 49 years or older, living in the Blue Mountains, west of Sydney. Vertical disc diameter and VCDR were determined by planimetry from stereo optic disc photographs. The distribution of VCDR and percentiles (95th, 97.5th, 99th) were calculated. >Results: 6678 eyes were included in the analysis. Median cup to disc ratio, 95th, 97.5th, and 99th percentile increased with vertical optic disc diameter in a linear fashion. An increase of 0.2 in median VCDR (0.35 to 0.55) was observed between small (1.1–1.3 mm) and large (1.8–2.0 mm) optic discs. An equivalent increase of 0.2 (0.59 to 0.74) was observed for the 97.5th percentile from small to large discs. >Conclusion: VCDR percentiles for a “normal” population, adjusted for vertical optic disc diameter are presented. One quarter of all discs fell within the small or large disc categories highlighting the importance for estimating optic disc size. These data may assist in the diagnosis of glaucoma in clinical practice as well as providing a normative database. Sole use of VCDR percentile cut offs in defining glaucoma cases in population surveys requires further validation.
机译:>目的:垂直杯对椎间盘比率(VCDR)的97.5%已被建议作为有助于人群研究中青光眼诊断的有用工具。以前的VCDR百分位数报告尚未针对椎间盘大小进行调整,或者已通过基于小型医院的队列研究进行回归分析计算得出。作者的目的是在基于人群的大型样本中生成VCDR百分位数。 >方法:数据收集自居住在悉尼西部蓝山山脉的3654位年龄在49岁以上的人。垂直圆盘直径和VCDR通过立体视盘照片的平面测量法确定。计算了VCDR和百分位数(第95、97.5、99位)的分布。 >结果:分析中包括6678眼。杯状体与椎间盘的中位数比率(第95、97.5和99%)随着垂直视盘直径的线性增加。小型(1.1–1.3 mm)光盘和大型(1.8–2.0 mm)光盘之间的中值VCDR增加了0.2(0.35至0.55)。从小光盘到大光盘,第97.5个百分位数的当量增加了0.2(0.59至0.74)。 >结论:显示了针对“正常”人群的VCDR百分位数,并针对垂直视盘直径进行了调整。所有光盘中有四分之一属于小型或大型光盘类别,这突出了估算光盘大小的重要性。这些数据可以在临床实践中协助青光眼的诊断,并提供规范的数据库。在人口调查中,在定义青光眼病例中单独使用VCDR百分位数临界值需要进一步验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号