首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema
【2h】

Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema

机译:栅格激光治疗糖尿病性黄斑水肿后扫描激光衍生的水肿指数与视觉功能的相关性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Aim: To correlate change of an oedema index derived by scanning laser tomography with change of visual function in patients undergoing grid laser photocoagulation for clinically significant diabetic macular oedema (DMO).>Methods: The sample comprised 24 diabetic patients with retinal thickening within 500 μm of the fovea. Inclusion criteria included a logMAR visual acuity of 0.25, or better. Patients were assessed twice before a single session of grid laser treatment and within 1 week of, and at 1, 2, 4, and 12 weeks after, treatment. At each visit, patients underwent logMAR visual acuity, conventional and short wavelength automated perimetry (SWAP), and scanning laser tomography. Each visual function parameter was correlated with the mean oedema index. The mean oedema index represented the z-profile signal width divided by the maximum reflectance intensity (arbitrary units). A Pearson correlation coefficient (Bonferroni corrected) was undertaken on the data set of each patient.>Results: 13 patients exhibited significant correlation of the mean oedema index and at least one measure of visual function for the 10° × 10° scan field while 10 patients correlated for the 20° × 20° scan field. Seven patients demonstrated correlation for both scan fields. Laser photocoagulation typically resulted in an immediate loss of perimetric sensitivity whereas the oedema index changed over a period of weeks. Localised oedema did not impact upon visual acuity or letter contrast sensitivity when situated extrafoveally.>Conclusions: Correlation of change of the oedema index and of visual function following grid laser photocoagulation was not found in all patients. An absence of correlation can be explained by the localised distribution of DMO in this sample of patients, as well as by differences in the time course of change of the oedema index and visual function. The study has objectively documented change in the magnitude and distribution of DMO following grid laser treatment and has established the relation of this change to the change in visual function.
机译:>目标:将具有临床意义的糖尿病性黄斑水肿(DMO)的栅格激光光凝术患者的扫描激光断层扫描得出的水肿指数变化与视觉功能变化相关联。>方法:样本包括24名糖尿病患者,视网膜中央凹500μm以内视网膜增厚。纳入标准包括logMAR视力为0.25或更高。在一次网格激光治疗之前以及治疗1周内,1、2、4和12周后对患者进行两次评估。每次访视时,患者均接受logMAR视敏度,常规和短波自动视野检查(SWAP)以及扫描激光断层扫描。每个视觉功能参数都与平均水肿指数相关。平均水肿指数代表z轮廓信号宽度除以最大反射强度(任意单位)。在每个患者的数据集上进行皮尔逊相关系数(经邦费罗尼校正)。>结果: 13个患者在10°×时,平均水肿指数和至少一种视觉功能指标呈显着相关性。 10°扫描视野,而10位患者与20°×20°扫描视野相关。七个患者在两个扫描场上均表现出相关性。激光光凝通常会导致眼周敏感性立即丧失,而水肿指数会在数周内发生变化。 >结论:未在所有患者中发现网格激光光凝后水肿指数变化与视觉功能的相关性。结论:缺乏相关性可以通过在该患者样本中DMO的局部分布以及水肿指数和视觉功能变化的时程差异来解释。该研究客观地记录了栅格激光治疗后DMO大小和分布的变化,并建立了这种变化与视觉功能变化之间的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号