Aim: To investigate the safety and efficacy of the Zeiss Visulas II diode laser system in the reduction of intraocular pressure (IOP) in patients with complex glaucoma.Methods: The authors analysed the medical records of patients who underwent trans-scleral diode laser cycloablation (TDC) at the Manchester Royal Eye Hospital during a 34 month period. 55 eyes of 53 patients with complex glaucoma were followed up for a period of 12–52 months (mean 23.1 months) after initial treatment with the Zeiss Visulas II diode laser system.Results: Mean pretreatment IOP was 35.8 mm Hg (range 22–64 mm Hg). At the last examination, mean IOP was 17.3 mm Hg (range 0–40 mm Hg). After treatment, 45 eyes (82%) had an IOP between 5 and 22 mm Hg; in 46 eyes (84%) the preoperative IOP had been reduced by 30% or more. The mean number of treatment sessions was 1.7 (range 1–6). At the last follow up appointment, the mean number of glaucoma medications was reduced from 2.1 to 1.6 (p<0.05). In 10 eyes (18%), post-treatment visual acuity (VA) was worse than pretreatment VA by 2 or more lines.Conclusions: Treatment with the Zeiss Visulas II diode laser system can be safely repeated in order to achieve the target IOP. Treatment outcomes in this study were similar to those from previously published work using the Iris Medical Oculight SLx laser.
机译:目的:探讨Zeiss Visulas II二极管激光系统在降低复杂性青光眼患者眼内压(IOP)方面的安全性和有效性。方法:作者分析了经巩膜二极管激光环化消融术( TDC)在曼彻斯特皇家眼科医院接受了34个月的检查。在使用Zeiss Visulas II二极管激光系统进行初始治疗后,对53例复杂性青光眼患者的55只眼进行了12–52个月(平均23.1个月)的随访。结果:平均预处理IOP为35.8 mm Hg(范围22–64)毫米汞柱)。在最后一次检查中,平均眼压为17.3毫米汞柱(范围0–40毫米汞柱)。治疗后,有45只眼(82%)的IOP在5到22毫米汞柱之间;在46眼(84%)中,术前眼压降低了30%或更多。平均疗程为1.7(范围1-6)。在最后一次随访中,青光眼药物的平均使用量从2.1降低至1.6(p <0.05)。在10眼(18%)中,治疗后视力(VA)比治疗前VA差2条或更多行。结论:可以安全地重复使用Zeiss Visulas II二极管激光系统进行治疗,以达到目标IOP。该研究的治疗结果与先前使用Iris Medical Oculight SLx激光器发表的研究结果相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号