An investigation was undertaken into the relationship between the wet length of a standard Schirmer paper and the fluid weight in the 5 mm tip after a 5-minute moistening period. Immediate weighing after moistening showed that it is unreliable to infer a particular fluid weight in the 5 mm tip from a known wet length, and it is concluded that such papers will lead to error in lysozyme tests. If the papers are inserted for a period within sealed envelopes, there is found to be a close relationship between wet length and fluid weight in the tip, the papers reaching a stable state at 5 hours. Soaked Schirmer papers were shown to given particularly inconsistent results.
机译:在5分钟的润湿时间后,对标准Schirmer纸的湿长度与5 mm尖端中的流体重量之间的关系进行了研究。润湿后立即称重表明,从已知的湿长度推断5 mm吸头中的特定流体重量是不可靠的,并且得出的结论是,此类纸将导致溶菌酶测试错误。如果将纸插入密封的信封中一段时间​​,则发现纸头的湿长和流体重量之间存在密切关系,纸在5小时后达到稳定状态。浸透的Schirmer论文显示出特别不一致的结果。