首页> 美国卫生研究院文献>The Journal of Physiology >Accuracy of weight estimation for weights lifted by proximal and distal muscles of the human upper limb.
【2h】

Accuracy of weight estimation for weights lifted by proximal and distal muscles of the human upper limb.

机译:人体上肢近端和远端肌肉举起的重量的重量估算精度。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

1. It is well established that tactile acuity is greater over digits than over the proximal parts of the upper limb and that the corticospinal projection is especially dense for distal muscles. To determine whether the acuity for judgements of forces exerted by distal muscles differed from that for proximal muscles, a weight-matching task was used with first dorsal interosseous, flexor pollicus longus and elbow flexors. 2. Reference weights equivalent to approximately 3% (light) and 15% (heavy) of the maximal voluntary contraction were lifted by one muscle group on the left. They were matched with a variable weight, lifted by the same group, on the right. 3. In naive subjects, the coefficient of variation for repeated estimates of perceived heaviness was significantly lower for proximal than distal muscles. Measured in this way, 'accuracy' (i.e. reproducibility of the estimates) was not greater for the intrinsic muscles of the hand. This result could not be explained by the way in which the weights were supported by the index finger. When the data were expressed as the relative difference between the reference and the matched weight, each muscle group behaved similarly. 4. For a particular muscle, accuracy was greater when the heavy rather than the light weights were lifted. 5. Given that estimates of forces and heaviness are biased by signals of central motor command (McCloskey, 1981; Gandevia, 1987; Cafarelli, 1988; Jones, 1988). these signals could be graded no more finely for distal than proximal muscles. Furthermore, relative accuracy was greater for forces at the high rather than the low end of the comfortable 'matching' range of force for a particular muscle.
机译:1.公认的是,手指的触觉敏锐度高于上肢的近端触觉敏锐度,并且皮质脊髓突部对于远端肌肉特别密集。为了确定判断远端肌肉施加力的敏锐度是否与近端肌肉的敏锐度不同,将重量匹配任务与第一个背骨间,屈曲长直肌和肘屈肌一起使用。 2.左侧的一组肌肉抬起相当于最大自愿收缩力约3%(轻)和15%(重)的参考体重。他们与可变的重量相匹配,由同一组在右侧抬起。 3.在幼稚的受试者中,对近端肌肉的重复估计的重现性的变异系数显着低于远端肌肉。用这种方法测量,手的固有肌肉的``准确性''(即估计值的可重复性)并不更大。用食指支撑砝码的方式无法解释此结果。当数据表示为参考体重和匹配体重之间的相对差异时,每个肌肉组的行为类似。 4.对于特定的肌肉,举起重物而不是轻物时,准确性更高。 5.鉴于力和重量的估计值受到中央运动指挥信号的影响(McCloskey,1981; Gandevia,1987; Cafarelli,1988; Jones,1988)。对于远端肌肉,这些信号的分级可能不如近端肌肉。此外,对于特定肌肉来说,在舒适的“匹配”力范围的高端而不是低端,相对精度更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号