首页> 美国卫生研究院文献>British Journal of Sports Medicine >High reproducibility of patellar tendon vascularity assessed by colour Doppler ultrasonography: a reliable measurement tool for quantifying tendon pathology
【2h】

High reproducibility of patellar tendon vascularity assessed by colour Doppler ultrasonography: a reliable measurement tool for quantifying tendon pathology

机译:彩色多普勒超声评估assessed肌腱血管的高再现性:定量肌腱病理的可靠测量工具

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: This study examined whether patellar tendon vascularity could be quantified accurately in the clinical setting using colour Doppler ultrasonography. >Methods: A sonographer and two radiologists visually estimated tendon vascularity in millimetres in 74 tendons during ultrasound (US) examination and from hard copy films. These estimates were then compared to the length of vessels measured from the digital image in millimetres and the correlation between them was determined. A subset of 16 tendons was used to compare the estimates of vascularity by two examiners at US examination. >Results: The estimation of vascular length at US examination correlated highly with the measured vascular length (r = 0.92; 95% confidence interval (CI) 0.87 to 0.94), as did the length estimated from the films (r = 0.94; 95% CI 0.9 to 0.96). The correlation between examiners was 0.84 (95% CI 0.51 to 0.94) for the estimates made during US examination and 0.85 (95% CI 0.59 to 0.95) for the vessel lengths measured from the digital images. >Conclusions: These excellent correlations indicate that tendon vascularity can be reliably estimated using colour Doppler ultrasonography and tendon vascularity could therefore be used by clinicians to rate clinical change. This method of quantifying tendon vascularity could also be used in research to investigate the effects of tendon treatments on vascularity.
机译:>背景:该研究探讨了在临床环境中使用彩色多普勒超声检查是否可以准确定量pa骨肌腱血管的数量。 >方法:一名超声医师和两名放射科医生通过超声检查和从硬拷贝胶片上直观地估算了74根肌腱中的肌腱血管数(毫米)。然后将这些估计值与以毫米为单位的数字图像中测得的血管长度进行比较,并确定它们之间的相关性。 16名肌腱的子集被用于在美国检查时比较两名检查员的血管估计值。 >结果:US检查中血管长度的估计值与测得的血管长度高度相关(r = 0.92; 95%置信区间(CI)为0.87至0.94),从胶片中估计的长度也是如此( r = 0.94; 95%CI为0.9至0.96)。在美国检查期间,检查者之间的相关性是0.84(95%CI 0.51至0.94),对于从数字图像测量的血管长度,其相关性是0.85(95%CI 0.59至0.95)。 >结论:这些良好的相关性表明,使用彩色多普勒超声可以可靠地估计肌腱血管的形成,因此临床医生可以使用肌腱血管的形成来评价临床变化。这种定量肌腱血管的方法也可以用于研究肌腱治疗对血管的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号