首页> 美国卫生研究院文献>The Journal of Physiology >Variability of the relative preference for stimulus orientation and direction of movement in some units of the cat visual cortex (areas 17 and 18).
【2h】

Variability of the relative preference for stimulus orientation and direction of movement in some units of the cat visual cortex (areas 17 and 18).

机译:在猫视皮层的某些单位(区域17和18)中刺激方向和运动方向的相对偏爱性的变异性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

1. The responses to visual stimuli of single units in the cortex of cats anaesthetized with pentobarbitone were recorded extracellularly with glass micropipettes. All had receptive field centres more than 5 degrees and most lay between 5 and 20 degrees from the area centralis. Most units were in Area 18 but some were in the corresponding field representation in Area 17. 2. A quantitative method is described in which the visual stimuli (slits or light bars) were presented repetitively by mechanical means in each of four orientations of the stimulus and in two directions of movement for each orientation. The responses were analysed quantitatively and criteria are described for classification of units according to their preference for particular orientations or directions of movement of the stimulus. 3. Some units were studied continuously for up to 2 hr using the quantitative technique. In Area 18, of nineteen units, eighteen showed changes in their preference for direction of stimulus movement and, in seven of eleven units, the orientation preference changed. In Area 17 direction preference changed in eight of nine units and orientation preference in six of seven. In some cases both orientation and direction preference altered. 4. The relationship of these changes to alterations in the 'spontaneous activity' of the cortical units and to variations in the depth of anaesthesia are considered. Neither would appear to be the sole cause of the phenomenon.
机译:1.用玻璃微量移液器在细胞外记录用戊巴比妥麻醉的猫皮层中单个单位对视觉刺激的反应。所有人的感受野中心都超过5度,并且大多数位于距中心区域5至20度之间。大多数单位位于区域18中,而某些单位位于区域17中的相应字段表示中。2.描述了一种定量方法,其中通过机械方式在刺激的四个方向中的每个方向重复显示视觉刺激(狭缝或光条)并针对每个方向在两个运动方向上移动。定量分析了响应,并描述了根据单元对刺激的特定方向或运动方向的偏好对单元进行分类的标准。 3.使用定量技术,对某些单位进行了长达2小时的连续研究。在18个区域的19个单位中,有18个区域显示出他们对刺激运动方向的偏好发生了变化,而在11个单元中的七个区域中,方向偏好发生了变化。在区域17中,方向偏好更改为9个单元中的8个,而方向偏好更改为7个单元中的6个。在某些情况下,方向和方向偏好都发生了变化。 4.考虑了这些变化与皮层单位“自发活动”的变化以及麻醉深度变化之间的关系。似乎都不是造成这种现象的唯一原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号