IntroductionIonized calcium (iCa) concentration is often used in critical care and measured using blood gas analyzers at the point of care. Controlling and adjusting regional citrate anticoagulation (RCA) for continuous renal replacement therapy (CRRT) involves measuring the iCa concentration in two samples: systemic with physiological iCa concentrations and post filter samples with very low iCa concentrations. However, modern blood gas analyzers are optimized for physiological iCa concentrations which might make them less suitable for measuring low iCa in blood with a high concentration of citrate. We present results of iCa measurements from six different blood gas analyzers and the impact on clinical decisions based on the recommendations of the dialysis’ device manufacturer.
机译:简介离子钙(iCa)浓度通常用于重症监护中,并在护理时使用血气分析仪进行测量。控制和调整局部柠檬酸抗凝(RCA)以进行连续性肾脏替代治疗(CRRT)涉及测量两个样品中的iCa浓度:具有生理性iCa浓度的全身性样品和具有非常低的iCa浓度的后过滤器样品。但是,现代血气分析仪针对生理性iCa浓度进行了优化,这可能使它们不太适合于测量柠檬酸浓度高的血液中的低iCa。我们根据透析设备制造商的建议,介绍了六种不同的血气分析仪进行的iCa测量结果以及对临床决策的影响。