Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient

机译:头朝下位置和呼吸对呼吸功能的影响在插入监控器时用窗帘将脸部完全遮盖心脏外科病人的导管

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Background:We evaluated the effect on the respiratory gas exchange of the 30° head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two manoeuvres, 20 coronary patients and 10 patients with end-stage heart disease were supplied with oxygen (FiO2 =0.4) by a Venturi mask, while 20 coronary patients breathed room air. The arterial blood samples to measure oxygen (PaO2) and carbon dioxide (PaCO2) tension and oxygen saturation (SaO2) were analysed by a blood gas system.
机译:背景:我们评估了30°头朝下位置对呼吸气体交换的影响,并用无菌盖布完全覆盖了面部。这些用于插管颈内静脉并将肺动脉导管放置在心脏外科手术患者中。在两次手术中,通过文丘里面罩为20例冠状动脉患者和10例晚期心脏病患者提供了氧气(FiO2 = 0.4),而20例冠状动脉患者则呼吸了室内空气。通过血气系统分析了用于测量氧气(PaO2)和二氧化碳(PaCO2)张力和氧气饱和度(SaO2)的动脉血样。