The objective of the article is to describe the methodology followed to validate the finite element model for the new method of setting pipes in a separate sewer system, using one trench to accommodate the storm pipe over the sanitary pipe “doi.org/10.1016/j.tust.2019.103019” (Abbas et al., 2019). A physical model was established in the Liverpool John Moores University (LJMU) lab to test the structural performance of two PVC pipes buried in one trench. The results of the physical model were used to validate an FE model using the same material properties and boundary conditions used in the physical model. The validation process allowed the FE model to be upgraded to a 3D FE full-scale model for testing the novel method used to place the separate sewer system.
机译:本文的目的是描述用于验证在单独的下水道系统中设置管道的新方法的有限元模型所采用的方法,该方法使用一条沟槽将雨水管道容纳在卫生管道上方” doi.org/10.1016/j .tust.2019.103019”(Abbas等人,2019)。利物浦约翰摩尔大学(LJMU)实验室建立了物理模型,以测试埋在一个沟槽中的两条PVC管的结构性能。物理模型的结果用于验证FE模型,并使用与物理模型相同的材料属性和边界条件。验证过程允许将FE模型升级为3D FE满比例模型,以测试用于放置单独的下水道系统的新颖方法。