Eyes Open – Eyes Closed EEG/fMRI data set including dedicated Carbon Wire Loop motion detection channels

机译:睁眼–闭眼 EEG / fMRI数据集包括专用的碳线环运动检测通道

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This data set contains electroencephalography (EEG) data as well as simultaneous EEG with functional magnetic resonance imaging (EEG/fMRI) data. During EEG/fMRI, the EEG cap was outfitted with a hardware-based add-on consisting of carbon-wire loops (CWL). These yielded six extra׳CWL׳ signals related to Faraday induction of these loops in the main magnetic field “Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings” (Masterton et al., 2007) .In this data set, the CWL data make it possible to do a direct regression approach to deal with the BCG and specifically He artifact.The CWL-EEG/fMRI data in this paper has been recorded on two MRI scanners with different Helium pump systems (4 subjects on a 3 T TIM Trio and 4 subjects on a 3T VERIO). Separate EEG/fMRI data sets have been recorded for the helium pump ON as well as the helium pump OFF conditions. The EEG-only data (same subjects) has been recorded for a motion artifact-free reference EEG signal outside of the scanner.This paper also links to an EEGlab “EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis” (Delorme and Makeig, 2004) plugin to perform a CWL regression approach to deal with the He pump artifact, as published in the main paper “Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections-A validation of a real-time simultaneous EEG/fMRI correction method” (van der Meer et al., 2016) .
机译:该数据集包含脑电图(EEG)数据以及同时具有功能性磁共振成像(EEG / fMRI)数据的EEG。在EEG / fMRI期间,EEG帽配有基于硬件的附件,该附件由碳线环(CWL)组成。这些产生了六个额外的andCWL and信号,这些信号与法拉第感应磁场在主磁场“通过同时记录EEG和fMRI来测量和减少运动和心动图伪影”有关(Masterton等,2007)。在此数据集中, CWL数据使得可以进行直接回归方法来处理BCG,尤其是He伪影。本文中的CWL-EEG / fMRI数据已记录在两台具有不同氦泵系统的MRI扫描仪上(4位受试者在3 T TIM Trio和3T VERIO上的4个主题)。对于氦气泵开启和氦气泵关闭条件,分别记录了独立的EEG / fMRI数据集。仅EEG数据(相同的对象)已记录在扫描仪外部,用于无运动伪影的参考EEG信号。本文还链接到EEGlab“ EEGLAB:用于分析单次EEG动力学的开源工具箱,包括独立的组件分析”(Delorme和Makeig,2004)插件执行CWL回归方法来处理He泵伪像,如主要论文中所发表的“基于碳丝环的伪像校正优于后处理EEG / fMRI校正-A验证实时同步脑电图/功能磁共振成像校正方法”(van der Meer等,2016)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号