Failure of a vascular closure device most commonly results in a hemorrhage or pseudoaneurysm formation. In this paper a rare case of severe acute limb ischemia following incorrect deployment of a clip-based closure device (Starclose SE, Abbott Vascular) in a 31-year-old woman is presented. Symptoms of acute limb ischemia occurred at the start of the ambulation, 6 h after completion of the procedure. Because of the severity of ischemia the patient was treated surgically, and limb perfusion was successfully restored. An attempt of closure of an inadvertently punctured narrow superficial femoral artery was identified as the cause of this complication.
机译:血管闭合装置的故障通常导致出血或假性动脉瘤的形成。本文介绍了在31岁的女性中错误部署基于夹子的闭合装置(Starclose SE,Abbott Vascular)后发生的严重急性肢体缺血的罕见病例。急性肢体缺血的症状发生在步行开始时,即手术完成后6小时。由于缺血的严重性,需要对患者进行手术治疗,并成功恢复了肢体灌注。尝试闭合无意穿刺的狭窄股浅动脉被认为是造成这种并发症的原因。