Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?

机译:Biotronik除颤器导线中的外在导体和绝缘故障:历史重复还是虚假警报?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a “unique” failure mechanism: Cables externalize through the insulation (“inside-out” abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.
机译:召回的St. Jude Medical Riata植入式心脏复律除颤器(ICD)导线经常导致导体外部化和绝缘失效。导体外部化是一种“独特的”故障机制:电缆通过绝缘层进行外部化(“由内而外”的磨损)并出现在引线主体的外部。最近,有单个报告描述了Biotronik导线也有类似的故障。此外,一些研究报告称,与竞争对手相比,Biotronik Linox导线具有较高的电气故障率(不仅是绝缘故障),而且存活率降低。在本文中,我们描述了一例Biotronik Kentrox ICD引线的患者在荧光检查中表现出绝缘失效和导体外在化的迹象。由于拔除的风险很高,我们决定植入新的引线,放弃损坏的引线。铅再植情况良好。随后,我们回顾了有关Biotronik Kentrox和Linox ICD引线失效,尤其是外部导体的当前可用文献。一些单中心研究和一项无前瞻性的注册表显示,Linox引线在5年生存率在88%到91%之间,明显低于其他制造商。但是,两个正在进行的多中心,前瞻性注册表(GALAXY和CELESTIAL)的初步结果显示,植入后5年的存活率为96%,完全符合行业标准。需要持续的数据收集以确认该ICD导线系列的长期性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号