Technique and Considerations in the Use of 4x1 Ring High-definition Transcranial Direct Current Stimulation (HD-tDCS)

机译:使用4x1环形高清经颅直流电刺激(HD-tDCS)的技术和注意事项

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

High-definition transcranial direct current stimulation (HD-tDCS) has recently been developed as a noninvasive brain stimulation approach that increases the accuracy of current delivery to the brain by using arrays of smaller "high-definition" electrodes, instead of the larger pad-electrodes of conventional tDCS. Targeting is achieved by energizing electrodes placed in predetermined configurations. One of these is the 4x1-ring configuration. In this approach, a center ring electrode (anode or cathode) overlying the target cortical region is surrounded by four return electrodes, which help circumscribe the area of stimulation. Delivery of 4x1-ring HD-tDCS is capable of inducing significant neurophysiological and clinical effects in both healthy subjects and patients. Furthermore, its tolerability is supported by studies using intensities as high as 2.0 milliamperes for up to twenty minutes.Even though 4x1 HD-tDCS is simple to perform, correct electrode positioning is important in order to accurately stimulate target cortical regions and exert its neuromodulatory effects. The use of electrodes and hardware that have specifically been tested for HD-tDCS is critical for safety and tolerability. Given that most published studies on 4x1 HD-tDCS have targeted the primary motor cortex (M1), particularly for pain-related outcomes, the purpose of this article is to systematically describe its use for M1 stimulation, as well as the considerations to be taken for safe and effective stimulation. However, the methods outlined here can be adapted for other HD-tDCS configurations and cortical targets.
机译:高清晰度经颅直流电刺激(HD-tDCS)最近作为一种非侵入性的脑部刺激方法而得到开发,该方法通过使用较小的“高清晰度”电极阵列(而不是较大的pad)来提高向大脑的电流传输准确性。传统tDCS的电极。通过激励以预定配置放置的电极来实现目标。其中之一是4x1环配置。在这种方法中,覆盖目标皮层区域的中央环形电极(阳极或阴极)被四个返回电极围绕,这有助于限制刺激区域。传递4x1环HD-tDCS能够在健康受试者和患者中诱导明显的神经生理和临床效果。此外,它的耐受性得到了高达20分钟的高达2.0毫安的强度的研究的支持。即使4x1 HD-tDCS易于执行,正确的电极定位对于准确刺激靶皮层区域并发挥其神经调节作用也很重要。 。对于HD-tDCS,经过专门测试的电极和硬件的使用对于安全性和耐受性至关重要。鉴于大多数已发表的有关4x1 HD-tDCS的研究都针对主运动皮层(M1),尤其是针对疼痛相关的结局,因此本文的目的是系统地描述其对M1刺激的用途以及需要考虑的因素进行安全有效的刺激。但是,此处概述的方法可适用于其他HD-tDCS配置和皮质目标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号