Actigraphy has become a common method of measuring sleep due to its non-invasive, cost-effective nature. An actigraph (Readiband™) that utilizes automatic scoring algorithms has been used in the research, but is yet to be evaluated for its inter-device reliability. A total of 77 nights of sleep data from 11 healthy adult participants was collected while participants were concomitantly wearing two Readiband™ actigraphs attached together (ACT1 and ACT2). Sleep indices including total sleep time (TST), sleep latency (SL), sleep efficiency (SE%), wake after sleep onset (WASO), total time in bed (TTB), wake episodes per night (WE), sleep onset variance (SOV) and wake variance (WV) were assessed between the two devices using mean differences, 95% levels of agreement, intraclass correlation coefficients (ICC), typical error of measurement (TEM) and coefficient of variation (CV%) analysis. There were no significant differences between devices for any of the measured sleep variables (p>0.05). TST, SE, SL, TTB, SOV and WV all resulted in very high ICC's (>0.90), with WASO and WE resulting in high ICC's between devices (0.85 and 0.80, respectively). Mean differences of −2.1 and 0.2 min for TST and SL were associated with a low TEM between devices (9.5 and 3.8 min, respectively). SE resulted in a 0.3% mean difference between devices. The Readiband™ is a reliable tool for researchers using multiple devices of this brand in sleep studies to assess basic measures of sleep quality and quantity in healthy adult populations.
机译:书法由于其非侵入性的,具有成本效益的性质,已经成为测量睡眠的一种常用方法。在研究中已经使用了利用自动评分算法的活动记录仪(Readiband™),但尚需对其设备间的可靠性进行评估。收集了11位健康成人参与者的总计77夜睡眠数据,而参与者同时佩戴了两副Readiband™手写笔(ACT1和ACT2)。睡眠指数包括总睡眠时间(TST),睡眠潜伏期(SL),睡眠效率(SE%),入睡后醒来(WASO),床上总时间(TTB),每晚醒来次数(WE),入睡变化(SOV)和唤醒方差(WV)使用均值差,95%一致性水平,组内相关系数(ICC),典型测量误差(TEM)和变异系数(CV%)分析进行评估。对于任何测得的睡眠变量,设备之间均无显着差异(p> 0.05)。 TST,SE,SL,TTB,SOV和WV均导致非常高的ICC(> 0.90),而WASO和WE导致器件之间的ICC很高(分别为0.85和0.80)。 TST和SL的-2.1和0.2min的平均差异与器件之间的TEM低有关(分别为9.5和3.8min)。 SE导致设备之间的平均差异为0.3%。对于在睡眠研究中使用该品牌多个设备的研究人员,评估健康成年人口中睡眠质量和数量的基本指标,Readiband™是可靠的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号