首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Acoustic Localization of Bragg Peak Proton Beams for Hadrontherapy Monitoring
【2h】

Acoustic Localization of Bragg Peak Proton Beams for Hadrontherapy Monitoring

机译:布拉格峰质子束的声波定位用于强子疗法监测

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Hadrontherapy makes it possible to deliver high doses of energy to cancerous tumors by using the large energy deposition in the Bragg-peak. However, uncertainties in the patient positioning and/or in the anatomical parameters can cause distortions in the calculation of the dose distribution. In order to maximize the effectiveness of heavy particle treatments, an accurate monitoring system of the deposited dose depending on the energy, beam time, and spot size is necessary. The localized deposition of this energy leads to the generation of a thermoacoustic pulse that can be detected using acoustic technologies. This article presents different experimental and simulation studies of the acoustic localization of thermoacoustic pulses captured with a set of sensors around the sample. In addition, numerical simulations have been done where thermo-acoustic pulses are emitted for the specific case of a proton beam of 100 MeV.
机译:强子疗法通过利用布拉格峰中的大量能量沉积,可以向癌性肿瘤传递高剂量的能量。但是,患者位置和/或解剖学参数的不确定性可能导致剂量分布计算中的失真。为了使重颗粒处理的效率最大化,必须根据能量,束流时间和光斑大小对沉积剂量进行精确的监控。该能量的局部沉积导致可以使用声学技术检测到的热声脉冲的产生。本文介绍了用样品周围的一组传感器捕获的热声脉冲的声定位的不同实验和模拟研究。此外,已经进行了数值模拟,其中针对100 MeV质子束的特定情况发射了热声脉冲。