The non-invasive fetal electrocardiogram (fECG) technique has recently received considerable interest in monitoring fetal health. The aim of our paper is to propose a novel fECG algorithm based on the combination of the criteria of independent source separation and of a quality index optimization (ICAQIO-based). The algorithm was compared with two methods applying the two different criteria independently—the ICA-based and the QIO-based methods—which were previously developed by our group. All three methods were tested on the recently implemented Fetal ECG Synthetic Database (FECGSYNDB). Moreover, the performance of the algorithm was tested on real data from the PhysioNet fetal ECG Challenge 2013 Database. The proposed combined method outperformed the other two algorithms on the FECGSYNDB (ICAQIO-based: 98.78%, QIO-based: 97.77%, ICA-based: 97.61%). Significant differences were obtained in particular in the conditions when uterine contractions and maternal and fetal ectopic beats occurred. On the real data, all three methods obtained very high performances, with the QIO-based method proving slightly better than the other two (ICAQIO-based: 99.38%, QIO-based: 99.76%, ICA-based: 99.37%). The findings from this study suggest that the proposed method could potentially be applied as a novel algorithm for accurate extraction of fECG, especially in critical recording conditions.
机译:非侵入性胎儿心电图(fECG)技术最近在监视胎儿健康方面引起了相当大的兴趣。本文的目的是提出一种基于独立源分离标准和质量指标优化(基于ICAQIO)标准相结合的新型fECG算法。将算法与分别应用两种不同标准的两种方法(基于ICA的方法和基于QIO的方法)进行了比较,这是我们小组先前开发的。这三种方法均在最近实施的胎儿ECG合成数据库(FECGSYNDB)上进行了测试。此外,该算法的性能已在PhysioNet胎儿ECG挑战2013数据库的真实数据上进行了测试。所提出的组合方法在FECGSYNDB上的性能优于其他两种算法(基于ICAQIO的为98.78%,基于QIO的为97.77%,基于ICA的为97.61%)。特别是在发生子宫收缩以及母婴异位搏动的情况下,存在显着差异。在实际数据上,这三种方法均具有很高的性能,基于QIO的方法被证明比其他两种方法稍好(基于ICAQIO的方法:99.38%;基于QIO的方法:99.76%;基于ICA的方法:99.37%)。这项研究的发现表明,所提出的方法有可能被用作准确提取fECG的新算法,尤其是在关键的记录条件下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号