首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Sensors for Highly Toxic Gases: Methylamine and Hydrogen Chloride Detection at Low Concentrations in an Ionic Liquid on Pt Screen Printed Electrodes
【2h】

Sensors for Highly Toxic Gases: Methylamine and Hydrogen Chloride Detection at Low Concentrations in an Ionic Liquid on Pt Screen Printed Electrodes

机译:高毒性气体传感器:Pt丝网印刷电极上离子液体中低浓度的甲胺和氯化氢检测

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Commercially available Pt screen printed electrodes (SPEs) have been employed as possible electrode materials for methylamine (MA) and hydrogen chloride (HCl) gas detection. The room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) was used as a solvent and the electrochemical behaviour of both gases was first examined using cyclic voltammetry. The reaction mechanism appears to be the same on Pt SPEs as on Pt microelectrodes. Furthermore, the analytical utility was studied to understand the behaviour of these highly toxic gases at low concentrations on SPEs, with calibration graphs obtained from 10 to 80 ppm. Three different electrochemical techniques were employed: linear sweep voltammetry (LSV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV), with no significant differences in the limits of detection (LODs) between the techniques (LODs were between 1.4 to 3.6 ppm for all three techniques for both gases). The LODs achieved on Pt SPEs were lower than the current Occupational Safety and Health Administration Permissible Exposure Limit (OSHA PEL) limits of the two gases (5 ppm for HCl and 10 ppm for MA), suggesting that Pt SPEs can successfully be combined with RTILs to be used as cheap alternatives for amperometric gas sensing in applications where these toxic gases may be released.
机译:市场上可买到的Pt丝网印刷电极(SPEs)已被用作检测甲胺(MA)和氯化氢(HCl)气体的电极材料。使用室温离子液体(RTIL)1-乙基-3-甲基咪唑双(三氟甲基磺酰基)酰亚胺([C2mim] [NTf2])作为溶剂,首先使用循环伏安法检查两种气体的电化学行为。在Pt SPE上的反应机理似乎与在Pt微电极上的反应机理相同。此外,还对分析工具进行了研究,以了解这些高毒性气体在SPE上低浓度时的行为,并获得了10至80 ppm的校准图。使用三种不同的电化学技术:线性扫描伏安法(LSV),差分脉冲伏安法(DPV)和方波伏安法(SWV),两种技术之间的检测限(LOD)均无显着差异(LOD在1.4至3.6之间)两种气体的所有三种技术的ppm)。在Pt SPE上实现的LOD低于当前两种气体的职业安全与健康管理局允许接触限值(OSHA PEL)限值(HCl为5 ppm,MA为10 ppm),这表明Pt SPE可以成功与RTIL结合在可能释放这些有毒气体的应用中,用作安培气体传感的廉价替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号