首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Amperometric Determination of Sulfite by Gas Diffusion-Sequential Injection with Boron-Doped Diamond Electrode
【2h】

Amperometric Determination of Sulfite by Gas Diffusion-Sequential Injection with Boron-Doped Diamond Electrode

机译:掺硼金刚石电极气体扩散-顺序注射安培法测定亚硫酸盐

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A gas diffusion sequential injection system with amperometric detection using a boron-doped diamond electrode was developed for the determination of sulfite. A gas diffusion unit (GDU) was used to prevent interference from sample matrices for the electrochemical measurement. The sample was mixed with an acid solution to generate gaseous sulfur dioxide prior to its passage through the donor channel of the GDU. The sulfur dioxide diffused through the PTFE hydrophobic membrane into a carrier solution of 0.1M phosphate buffer (pH 8)/0.1% sodium dodecyl sulfate in the acceptor channel of the GDU and turned to sulfite. Then the sulfite was carried to the electrochemical flow cell and detected directly by amperometry using the boron-doped diamond electrode at 0.95 V (versus Ag/AgCl). Sodium dodecyl sulfate was added to the carrier solution to prevent electrode fouling. This method was applicable in the concentration range of 0.2-20 mg SO32−/L and a detection limit (S/N = 3) of 0.05 mg SO32−/L was achieved. This method was successfully applied to the determination of sulfite in wines and the analytical results agreed well with those obtained by iodimetric titration. The relative standard deviations for the analysis of sulfite in wines were in the range of 1.0-4.1 %. The sampling frequency was 65 h−1.
机译:开发了一种使用硼掺杂金刚石电极进行安培检测的气体扩散顺序注入系统,用于测定亚硫酸盐。气体扩散单元(GDU)用于防止样品基质的干扰,进行电化学测量。在样品通过GDU的供体通道之前,先将其与酸性溶液混合以生成气态二氧化硫。二氧化硫通过PTFE疏水膜扩散到GDU受体通道中的0.1M磷酸盐缓冲液(pH 8)/0.1%十二烷基硫酸钠的载体溶液中,并转变为亚硫酸盐。然后将亚硫酸盐带入电化学流通池,并使用掺硼金刚石电极在0.95 V(相对于Ag / AgCl)下通过安培法直接检测。将十二烷基硫酸钠加入到载体溶液中以防止电极结垢。该方法适用于0.2-20 mg SO3 2- / L的浓度范围和0.05 mg SO3 2- /的检出限(S / N = 3)。达到了L。该方法已成功应用于葡萄酒中亚硫酸盐的测定,分析结果与碘量滴定法相吻合。分析葡萄酒中亚硫酸盐的相对标准偏差在1.0-4.1%的范围内。采样频率为65 h -1

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号