首页> 美国卫生研究院文献>Joints >Are Trabecular Metal Cones a Valid Option to Treat Metaphyseal Bone Defects in Complex Primary and Revision Knee Arthroplasty?
【2h】

Are Trabecular Metal Cones a Valid Option to Treat Metaphyseal Bone Defects in Complex Primary and Revision Knee Arthroplasty?

机译:小梁金属锥体是否是治疗复杂的原发和翻修膝关节置换术中的干phy端骨缺损的有效选择?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose  Metaphyseal bone defects are a challenge in complex primary and revision total knee arthroplasty (TKA). Recently, several studies have been published with promising results about the use of Trabecular Metal (TM) cones to address bone defects. The aim of this study is to review the literature to assess the efficacy of TM cones to address metaphyseal bone loss. >Methods  A comprehensive search was performed on PubMed, Medline, CINAHL, Cochrane, Embase, and Google Scholar databases using various combinations of the following keywords: “metaphyseal,” “cones,” “tantalum,” “knee,” and “revision.” Only papers reporting clinical data about the use of trabecular metal cones were included in the analysis. In vitro studies, case reports, surgical technique, or other studies where it was not possible to collect clinical data were excluded. Patients characteristics, details of the surgical procedures, outcome, and complications were collected from each included study. >Results  No controlled studies were available in the literature and all the papers were case series. In 16 studies included, the records of 442 patients with 447 implants and 523 TM cones were reported. The mean follow-up was 42 months (range: 5–105) for 360 procedures. Among 437 procedures, 30.4% were septic revisions. The Anderson Orthopaedic Research Institute (AORI) classification was available for 352 defects: 13 type 1, 69 type 2A, 115 type 2B, and 155 type 3. To manage these 352 defects, 360 TM cones were implanted. Intraoperative fractures occurred 13 times (10 femoral/3 tibial), 6 required surgical fixation. The overall infection rate was 7.38%, and the infection rate for the aseptic procedures was 0.99%. An aseptic exchange was performed 13 times, among these procedures two TM cones were loose. Signs of loosening were found just in 1.3% of the 523 TM cones implanted (5 femoral/2 tibial) during 447 procedures. >Conclusion  The TM cones are an effective solution to manage bone defects in complex primary and revision TKA at intermediate follow-up. The incidence of complications was low; however, the femoral metaphysis proved to be more susceptible to complications. >Level of Evidence  Level IV, systematic review of level IV studies.
机译:>目的干phy端骨缺损是复杂的原发和翻修全膝关节置换术(TKA)的挑战。近来,已经发表了一些关于使用小梁金属(TM)圆锥体解决骨缺损的研究,结果令人鼓舞。这项研究的目的是回顾文献以评估TM视锥解决干phy端骨丢失的功效。 >方法使用以下关键字的各种组合,对PubMed,Medline,CINAHL,Cochrane,Embase和Google Scholar数据库进行了全面搜索:“ met骨”,“锥体”,“钽”,“膝盖” ”和“修订”。分析仅包括报告有关使用小梁金属锥的临床数据的论文。体外研究,病例报告,手术技术或其他无法收集临床数据的研究均被排除在外。从每个纳入的研究中收集患者的特征,手术步骤,结果和并发症的细节。 >结果文献中没有对照研究,所有论文均为病例系列。在包括的16项研究中,报道了442例患者的记录,其中包括447个植入物和523个TM锥。 360次手术的平均随访时间为42个月(范围:5-105)。在437例手术中,有30.4%为脓毒症修订。安德森骨科研究所(AORI)的分类适用于352个缺陷:13型1、69型2A,115型2B和155型3。为处理这352个缺陷,植入了360 TM视锥。术中发生了13次骨折(10股/ 3胫骨骨折),其中6例需要手术固定。总体感染率为7.38%,无菌手术的感染率为0.99%。进行了13次无菌更换,在这些程序中,两个TM锥松了。在447例手术中,仅在植入的523 TM圆锥体(5个股骨/ 2个胫骨)中有1.3%出现了松动的迹象。 >结论 TM锥体是在中期随访中处理复杂的原发性和修订性TKA的骨缺损的有效解决方案。并发症的发生率很低;然而,事实证明,股骨干proved端更易发生并发症。 >证据级别:IV级,对IV级研究的系统评价。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号