Intravascular ultrasonography (IVUS) imaging is a user-friendly technique widely used during coronary interventions. An 80-year-old man was admitted with chest pain, and successful percutaneous coronary intervention was performed with stent implantation. One week later, the patient complained of further chest pain. Urgent coronary angiography showed total occlusion of the middle left anterior descending artery and the aspiration of thrombi was high. IVUS imaging showed inadequate stent strut apposition and distal dissection. We attempted another stent implantation but the IVUS catheter was stuck on the 0.014 inch wire. Therefore, we tried to pass the wire across the lateral side. After the wire was successfully passaged, the sprinter balloon was passed through the crushed stent to expand it. After 4 days later, the patient was discharged with no symptoms or electrocardiographic change.
机译:血管内超声(IVUS)成像是一种在冠状动脉介入治疗期间广泛使用的用户友好技术。一名80岁的男子因胸痛入院,并通过支架植入术成功进行了经皮冠状动脉介入治疗。一周后,患者抱怨胸部进一步疼痛。紧急冠状动脉造影显示左中前降支动脉完全闭塞,血栓抽吸高。 IVUS成像显示支架撑杆并置和远端解剖不足。我们尝试再次植入支架,但IVUS导管卡在0.014英寸的导线上。因此,我们尝试将导线穿过侧面。导线成功通过后,短跑气球穿过破碎的支架使其膨胀。 4天后,患者出院,无症状或心电图改变。