首页> 美国卫生研究院文献>Ultrasound: Journal of the British Medical Ultrasound Society >The effect of body position on developing ultrasound criteria for the assessment of the internal jugular vein
【2h】

The effect of body position on developing ultrasound criteria for the assessment of the internal jugular vein

机译:身体位置对制定超声评估颈内静脉的标准的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Recent studies investigating chronic cerebrospinal venous insufficiency highlighted that intracranial venous return has not yet been routinely investigated by ultrasound in the normal population. This creates an absence of a reference standard and raises concerns that the approach introduces variations into the results. The primary objective of this study was to develop reference standards for the assessment of the internal jugular vein in a normal population. A prospective small-scale study was conducted. Internal jugular veins of 31 normal candidates were examined using B-Mode and PW Doppler. Measurements at proximal and mid-point internal jugular vein were taken in sitting (90°) and supine (0°) positions. Area measurements were taken during passive respiration in cm2. Time average velocity measurements were taken during passive respiration over a 3-second period. Reflux measurements were taken after apnoea and reflux was recorded from any reversed flow. Measurements were taken three times; an average was calculated and statically analysed. Of the 31 participants, one was excluded from the study and 30 were suitable. The Mann-Whitney U test was used to analyse the results; all results (area, time average velocity and reflux) showed that there was a significant difference between the two positions with p < 0.05 (two-tailed). This pilot study does suggest that there is a significant difference in area, time average velocity and reflux measurements of the internal jugular vein when taken in the sitting and supine position, which could affect the outcome of chronic cerebrospinal venous insufficiency. A further large-scale study is required to validate and standardise the assessment of the internal jugular vein.
机译:近期研究慢性脑脊髓静脉功能不全的研究强调,在正常人群中,颅内静脉回流尚未通过超声常规检查。这会导致缺少参考标准,并引起关注,即该方法会在结果中引入差异。这项研究的主要目的是为正常人群的颈内静脉评估制定参考标准。进行了一项前瞻性的小规模研究。使用B型和PW多普勒检查了31名正常人的颈内静脉。在坐位(90°)和仰卧位(0°)进行颈近端和中点颈内静脉的测量。在被动呼吸过程中以cm 2 进行面积测量。在3秒的被动呼吸过程中进行了时间平均速度测量。呼吸暂停后进行反流测量,并记录任何逆流的回流。测量进行了三次。计算平均值并进行静态分析。在31名参与者中,有1名被排除在研究之外,另有30名合适。用Mann-Whitney U检验分析结果。所有结果(面积,时间平均速度和回流)均显示两个位置之间存在显着差异,p <0.05(两尾)。这项初步研究确实表明,坐位和仰卧位时颈内静脉的面积,时间平均速度和反流测量值存在显着差异,这可能会影响慢性脑脊髓静脉功能不全的结果。需要进一步的大规模研究以验证和标准化颈内静脉的评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号