首页> 美国卫生研究院文献>Toxicological Research >Real-time Detection of Trace Copper in Brain and Kidney of Fish for Medical Diagnosis
【2h】

Real-time Detection of Trace Copper in Brain and Kidney of Fish for Medical Diagnosis

机译:鱼类脑和肾脏中痕量铜的实时检测以进行医学诊断

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

For the detection of trace copper to be used in medical diagnosis, a sensitive handmade carbon nanotube paste electrode (PE) was developed using voltammetry. Analytical optimized conditions were found at 0.05 V anodic peak current. In the same conditions, various common electrodes were compared using stripping voltammetry, and the PE was found to be more sharply sensitive than other common electrodes. At optimum conditions, the working ranges of 3~19 μgL−1 were obtained. The relative standard deviation of 70.0 μgL−1 was determined to be 0.117% (n = 15), and the detection limit (S/N) was found to be 0.6 μgL−1 (9.4 × 10−9 M). The results were applied in detecting copper traces in the kidney and the brain cells of fish.
机译:为了检测用于医疗诊断的痕量铜,使用伏安法开发了灵敏的手工碳纳米管糊状电极(PE)。在0.05 V阳极峰值电流下发现了分析优化的条件。在相同条件下,使用溶出伏安法比较了各种公共电极,发现PE比其他公共电极更为灵敏。在最佳条件下,工作范围为3〜19μgL -1 。测定的相对标准偏差为70.0μgL -1 为0.117%(n = 15),检测极限(S / N)为0.6μgL -1 (9.4×10 −9 M)。该结果用于检测鱼类肾脏和脑细胞中的铜痕迹。