首页> 美国卫生研究院文献>Disease Markers >Within-Subject Reliability and between-Subject Variability of Oxidative Stress Markers in Saliva of Healthy Subjects: A Longitudinal Pilot Study
【2h】

Within-Subject Reliability and between-Subject Variability of Oxidative Stress Markers in Saliva of Healthy Subjects: A Longitudinal Pilot Study

机译:健康受试者唾液中氧化应激标记物的受试者间可靠性和受试者间变异性:一项纵向试验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study evaluated diurnal variations and day-to-day fluctuations of salivary oxidative stress (OS) markers in healthy adult individuals. Whole unstimulated saliva was collected at 2 time intervals over 3 consecutive days. Glutathione peroxidase (GPX), superoxide dismutase (SOD), total antioxidant capacity (TAC), and uric acid (UA) were analyzed using spectrophotometric methods, while 8-hydroxydeoxyguanosine (8-OHdG) and malondialdehyde (MDA) were determined using immunoassays. No significant differences for salivary OS markers between men and women were observed. For all examined OS markers, no significant day-to-day variations were demonstrated. Significant diurnal variations were found in salivary GPX, TAC and MDA levels. For SOD, TAC, GPX, and UA, good-to-moderate intraindividual coefficients of variations (CVs) were observed in more than 75% of the subjects. For MDA and 8-OHdG, intraindividual CVs > 35% were observed in 60% and 40% of the subjects, respectively. Between-subject variance was wide for all examined OS markers (CV% 30.08%–85.70%). Due to high intraindividual variability in the salivary concentrations of MDA and 8-OHdG, those markers cannot be reliably verified based on single measurements and multiple measurements over several days would provide more reliable information. Salivary SOD, TAC, GPX, and UA proved stable across three days of measurement. Trial Registration. ClinicalTrials.gov . Registered on 2017-01-19.
机译:本研究评估了健康成年个体唾液氧化应激(OS)标志物的昼夜变化和每日波动。在连续3天中以2个时间间隔收集全部未刺激的唾液。谷胱甘肽过氧化物酶(GPX),超氧化物歧化酶(SOD),总抗氧化能力(TAC)和尿酸(UA)使用分光光度法进行了分析,而8-羟基脱氧鸟苷(8-OHdG)和丙二醛(MDA)则采用免疫分析法进行了测定。男女唾液OS标记物之间无显着差异。对于所有检查的OS标记,均未显示出明显的日常变化。唾液中GPX,TAC和MDA的水平存在明显的昼夜变化。对于SOD,TAC,GPX和UA,在超过75%的受试者中观察到良好至中度的车内个体变异系数(CV)。对于MDA和8-OHdG,分别在60%和40%的受试者中观察到了个体内CVs> 35%。所有检查的OS指标的受试者间差异均很大(CV%30.08%–85.70%)。由于唾液中MDA和8-OHdG的浓度存在很大的个体差异,因此无法基于单次测量可靠地验证那些标记,而几天内的多次测量将提供更可靠的信息。在三天的测量中,唾液SOD,TAC,GPX和UA证明是稳定的。试用注册。 ClinicalTrials.gov。注册于2017-01-19。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号