The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18 adults, mostly white-collar workers, living in different bungalows located 190-240 feet from the line (exposed subjects) was compared to that of 17 adults living in similar residences far away from any transmission line. Each subject carried a Positron meter for 24 hr during 1 workday, which measured 60-Hz electric and magnetic fields every minute. All measurements were carried out in parallel for exposed and unexposed subjects during the same weeks between September and December. During measurements the average loading on the line varied between 600 and 1100 A. The average magnetic field intensity while at home was 4.4 times higher among exposed subjects than unexposed (7.1 versus 1.6 mG, p = 0.0001) and 6.2 times higher when considering only the sleeping period (6.8 versus 1.1 mG, p = 0.0001). Based on the 24-hr measurement, average magnetic field exposure was three times higher among the exposed. Electric field intensity was also higher among the exposed while at home (26.3 versus 14.0 V/m, p = 0.03). Magnetic field intensity among the exposed was positively correlated with the loading on the line (r = 0.8, p = 0.001). Percentage of time above a magnetic field threshold (2 mG or 7.8 mG) was a good indicator to distinguish the two types of exposure.(ABSTRACT TRUNCATED AT 250 WORDS)
机译:这项研究的目的是评估一条735kV输电线路对生活在该线路通行权边缘的人们的电场和磁场暴露的影响。将居住在距离该线190-240英尺的不同平房中的18位成年人(主要是白领)的暴露(暴露的对象)与居住在远离任何传输线的类似住宅中的17位成年人的暴露进行了比较。每位受试者在1个工作日内携带一个Positron仪表24小时,该仪表每分钟测量60 Hz的电场和磁场。在9月至12月的同一周内,对暴露和未暴露的受试者平行进行了所有测量。在测量过程中,线路上的平均负载在600至1100 A之间变化。暴露的对象在家中的平均磁场强度是未暴露的对象的4.4倍(7.1 vs 1.6 mG,p = 0.0001),而仅考虑以下因素则要高6.2倍。睡眠时间(6.8对1.1 mG,p = 0.0001)。根据24小时测量,平均磁场暴露量是暴露的磁场强度的三倍。暴露时在家中的电场强度也更高(26.3对14.0 V / m,p = 0.03)。暴露的磁场强度与线路上的负荷呈正相关(r = 0.8,p = 0.001)。高于磁场阈值(2 mG或7.8 mG)的时间百分比是区分两种暴露的好指标(摘要截断为250字)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号