The sporicidal activity of two solutions which have been used in the production of 'sterile' pre-injection swabs has been investigated. Propylene oxide (3.4% w/w) and chlorhexidine diacetate (0.6% w/w), both made up in approximately 65% w/w propan-2-ol, were artificially contaminated with spores of Bacillus subtilis var. niger and swabs were impregnated with these; surviving spores were enumerated at various temperatures and times of storage. Chlorhexidine diacetate had no sporicidal activity, whereas the activity of propylene oxide was dependent on temperature. The former should not be considered a sterilant and the latter can only be considered such if a controlled incubation period at an elevated temperature is employed.
机译:已经研究了用于“无菌”注射前拭子生产的两种溶液的杀孢活性。枯草芽孢杆菌(Bacillus subtilis var)的孢子人工污染了环氧丙烷(3.4%w / w)和氯己定二乙酸酯(0.6%w / w),两者均由约65%w / w的propan-2-ol组成。尼日尔和棉签都被这些浸渍了;在各种温度和储存时间下计数存活的孢子。二乙酸洗必泰没有杀孢子活性,而环氧丙烷的活性取决于温度。前者不应被视为灭菌剂,仅当在高温下采用受控的孵育时间时,才可以将后者视为灭菌剂。