首页> 美国卫生研究院文献>European Spine Journal >Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch
【2h】

Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch

机译:评估后路牙弓的解剖标志和安全区以确保将螺钉放置在地图集中

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Several studies have evaluated quantitative anatomic data for direct lateral mass screw fixation. To analyze anatomic landmarks and safe zones for optimal screw placement through the posterior arc of the human atlas, morphometric parameters of 41 adult native human atlas specimens were quantitatively measured. Internal dimensions of the atlas (lateral mass, maximum and minimum intraosseous screw length), minimum height and width of the posterior arc and optimal screw insertion angles were defined on pQCT scans. By this, an optimal posterior screw insertion point (OIP) and a preferable screw direction (PSD) through the posterior arch into the lateral mass of C1 were defined. External dimensions (transverse and sagittal diameter) as well as the width of the mid-portion of C1 lateral mass were significantly higher in male specimens. The mean height of the posterior arch at the vertebral artery groove was 4.1 ± 0.8 mm in female and 4.6 ± 0.9 mm in male specimens. The optimal screw insertion point was located 21.6 ± 1.7 mm in female and 23.6 ± 2.3 mm in male lateral from the posterior tubercle of C1 (P < 0.01). The preferable screw direction was a mean medial inclination of 7.9 ± 1.9° in female and 7.3 ± 2.7° in male specimens and a mean rostral direction of 2.4 ± 1.8° in female and 3.1 ± 1.7° in male specimens. In conclusion, the presented study provides information for the use and design of upper cervical spine instrumentation techniques, such as screw placement to C1 via the posterior arch. The characterization of working areas and safe zones (OIP, PSD) might contribute to a minimization of screw malposition in this highly demanding instrumentation technique.
机译:数项研究评估了直接侧块螺钉固定的定量解剖数据。为了分析解剖图样和安全区,以最佳地穿过人类地图集的后弧放置螺钉,对41个成年天然人类地图集标本的形态学参数进行了定量测量。在pQCT扫描中定义了图谱的内部尺寸(侧重,最大和最小骨内螺钉长度),后弧的最小高度和宽度以及最佳螺钉插入角度。这样,定义了最佳的后螺钉插入点(OIP)和通过后弓进入C1侧块的优选螺钉方向(PSD)。雄性标本的外部尺寸(横向和矢状直径)以及C1侧向肿块中部的宽度明显更高。雌性椎动脉槽后弓的平均高度为4.1±0.8mm,雄性标本为4.6±0.9mm。最佳螺钉插入点位于C1后结节的女性外侧21.6±1.7mm,男性外侧23.6±2.3mm(P <0.01)。最好的螺钉方向是女性的平均内侧倾斜度为7.9±1.9°,男性的平均倾斜度为7.3±2.7°,女性的平均鼻尖方向为2.4±1.8°,男性的平均鼻侧方向为3.1±1.7°。总之,本研究为上颈椎器械技术的使用和设计提供了信息,例如通过后牙弓将螺钉放置到C1上。在这种要求很高的仪器技术中,工作区域和安全区域(OIP,PSD)的特征可能有助于最大程度地减少螺钉错位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号