This work presents the design and evaluation of a fully wireless, multi-point temperature sensor system as a Process Analytical Technology (PAT) for lyophilization. Each sensor contains seven sensing elements which measure the product temperature at various positions of the contents of a glass vial. The sensor performance was studied by freeze drying experiments with sensor placement in both center and edge of full shelf of 6R glass vials with 4 ml fill volume. Product temperature profile and primary drying time measured at the bottom center position in the glass vial by the wireless sensor as well as the primary drying time are in close comparison with the thermocouple data. The drying times during primary drying were determined at the top, higher middle, lower middle and bottom positions which are 3.26 mm apart vertically in the vial by the wireless sensor based on the temperature profile measured at different positions. For a center vial, the drying time from the start of primary drying to each layer was measured at 3.9, 9.3, 14.2, and 21 h respectively, allowing to track the sublimation interface during primary drying phase. In addition, sublimation rate at each layer was calculated based on the drying time and theoretical weight loss of ice in the product. The sublimation rate at the beginning of the primary drying was similar to the sublimation rate by gravimetric method. Furthermore, the vial heat transfer coefficient (Kv) was also calculated based on the sublimation rate. Thus, allowing the use of the multi-point wireless sensor to rapidly monitor the sublimation rate and Kv for every batch as continuous process verification. Similar tests were also conducted with 3% w/v mannitol solutions and the results were consistent demonstrating potential for real-time monitoring, process verification and cycle optimization for pharmaceutical lyophilization.
机译:这项工作介绍了作为冻干过程分析技术(PAT)的全无线,多点温度传感器系统的设计和评估。每个传感器包含七个传感元件,可测量玻璃瓶中不同位置的产品温度。通过冷冻干燥实验对传感器性能进行了研究,将传感器放置在填充量为4 ml的6R玻璃小瓶的整个架子的中心和边缘。无线传感器在玻璃小瓶底部中心位置测量的产品温度曲线和一次干燥时间以及一次干燥时间与热电偶数据进行了比较。基于在不同位置测得的温度曲线,无线传感器在小瓶中垂直间隔3.26毫米的顶部,较高中部,较低中部和底部位置确定一次干燥期间的干燥时间。对于中心样品瓶,从初次干燥开始到每一层的干燥时间分别为3.9、9.3、14.2和21小时,从而可以追踪初次干燥阶段的升华界面。另外,基于干燥时间和产品中冰的理论重量损失来计算各层的升华率。初次干燥开始时的升华速率与重量分析法中的升华速率相似。此外,还基于升华率来计算瓶的传热系数(Kv)。因此,允许使用多点无线传感器快速监视每批的升华率和Kv,以进行连续过程验证。还对3%w / v甘露糖醇溶液进行了类似的测试,结果一致表明了对于药物冻干的实时监控,工艺验证和周期优化的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号