首页> 美国卫生研究院文献>Frontiers in Neurology >Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA
【2h】

Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

机译:卒中或TIA患者扩大心律监测的诊断率

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA.>Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented.>Results: One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2–14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0–99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration.>Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.
机译:>背景:评估短暂性脑缺血发作(TIA)或中风的房颤(AF)患者很重要,因为检测到AF会改变推荐的抗血栓形成方案,从使用抗血小板药物治疗改为口服抗凝。这项研究描述了基于贴剂的,一次性使用的,耐水的14天连续性心律监测仪(ZIO Patch)对中风或TIA患者的诊断率。>方法:我们获得了数据由ZIO补丁(iRhythm Technologies)的制造商和服务商提供。纳入2012年1月至2013年6月期间接受监测且监测指标为TIA或中风的患者。记录了监测的持续时间,心律不齐的数量和类型以及首次心律失常的时间。>结果:分析了117份监测报告。监护仪的平均磨损时间为10.9天,中值磨损时间为13.0天(四分位间距为7.2-14.0)。相对于总磨损时间的中值可分析时间为98.7%(IQR 96.0–99.5%)。 AF在所有报告中占5.0%。阵发性AF(PAF)首次发作前的平均持续时间为1.5天,中位持续时间为0.4天。第一次PAF发作的14.3%发生在48小时后。 PAF的平均负担为总监测持续时间的12.7%。>结论:出色的记录质量和非常好的患者依从性,再加上在监测的前48小时仍检测到大量的AF,这表明:对于患有卒中或TIA的患者,心脏补丁优于传统的48小时动态心电图监测仪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号