Radiographic Comparison between Cervical Spine Lateral and Whole-Spine Lateral Standing Radiographs

机译:颈椎侧位和全脊椎侧位片的放射学比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Study Design Retrospective radiologic study. >Objective The sagittal alignment of the cervical spine can be evaluated using either a lateral cervical radiograph or a whole-spine lateral view on which the cervical spine is included. To our knowledge, however, no report has compared the two. The purpose of this work is to identify the difference in radiographic parameters between the cervical spine lateral view and the whole-spine lateral view. >Methods We retrospectively analyzed 59 adult patients suffering from neck pain with cervical spine lateral radiographs and whole-spine lateral radiographs from November 2007 to December 2011. The radiographs were measured using standard techniques to obtain the following parameters from the two different radiographs: occipital–C2 angle, C2–C7 angle, C7–sternal angle, sternal slope, T1 slope, C2 central offset distance, the distance between C2 and C7 plumb lines, C4 anteroposterior (AP) diameter, the ratio of C2 central off distance to C4 AP diameter, the ratio of plumb lines' distance to C4 AP diameter. >Results We found that the occipital–C2 angle, sternal slope, and C4 AP diameter were similar, but the C2–C7 angle, C7–sternal angle, T1 slope, C2 central offset distance, distance between C2 and C7 plumb lines, ratio of C2 central off distance to C4 AP diameter, and ratio of plumb lines' distance to C4 AP diameter were different. However, the error of measurement was greater than the small angular and linear differences between the two views. >Conclusions Most numerical values of the measured radiographic parameters appear to be different between the two views. However, the two views are comparable because the numerical differences were smaller than the errors of measurement.
机译:>研究设计回顾性放射学研究。 >目的可以使用侧面颈椎X线照片或包括颈椎的全脊柱侧视图评估颈椎的矢状位。据我们所知,尚无报告将两者进行比较。这项工作的目的是确定颈椎侧面图和整个脊柱侧面图在放射线照相参数上的差异。 >方法我们回顾性分析了2007年11月至2011年12月的59例颈椎病成人患者的颈椎侧位X线照片和全脊椎侧位X射线照片。使用标准技术对X线照片进行测量,从中获得以下参数两种不同的射线照片:枕骨– C2角,C2 – C7角,C7 –胸骨角,胸骨斜率,T1斜率,C2中心偏移距离,C2和C7铅垂线之间的距离,C4前后(AP)直径,C2的比率中心偏移距离与C4 AP直径的关系,铅垂线距离与C4 AP直径的比率。 >结果我们发现枕骨– C2角,胸骨斜度和C4 AP直径相似,但C2–C7角,C7–胸骨角,T1斜度,C2中心偏移距离,C2之间的距离与C7铅垂线,C2中心距与C4 AP直径的比率以及铅垂线与C4 AP直径的比率不同。但是,测量误差大于两个视图之间较小的角度和线性差异。 >结论在两个视图之间,大多数测得的射线照相参数数值似乎不同。但是,这两种观点是可比较的,因为数值差异小于测量误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号