摘要

Sepsis and meningitis are life threatening medical conditions. Culture-based methods are used for identification of the causative pathogens, but they can be improved by implementation of additional test systems. We evaluated the performance of the novel FilmArray blood culture identification (BCID; Biofire Diagnostics) panel for rapid and accurate identification of microorganisms in positive blood cultures and additionally, in this cerebrospinal fluid (CSF) pilot study for direct testing of CSF. A total of 107 positive blood cultures and 20 CSF samples (positive and negative) were investigated and compared to the routine procedures. Of the 107 positive blood cultures, 90.7% (97/107) showed monomicrobial growth and 9.3% (10/107) polymicrobial growth. The FilmArray BCID panel covered 89.3% (25/28) of the bacteria and 100% (2/2) of the yeasts found in this study and accurately identified all of them.From the 20 retrospective analyzed CSF, in 9 positive specimens 6 different bacterial species were identified. Discrepant identification results were found in 25% (5/20) and a low sensitivity of 50% (95% CI of 15.7% to 84.3%) was detected.Our study confirms the FilmArray BCID panel as a rapid, easy to handle PCR system with a good performance in positive blood cultures without Gram-staining result. However, our results additionally suggest that the system is not useful for direct CSF testing due to poor sensitivity.
机译:败血症和脑膜炎是危及生命的医学疾病。基于培养的方法可用于确定病原体,但是可以通过实施其他测试系统来加以改进。我们评估了新型FilmArray血液培养物鉴定(BCID; Biofire Diagnostics)面板的性能,可快速,准确地鉴定阳性血液培养物中的微生物,此外,该脑脊液(CSF)初步研究还用于直接测试CSF。总共调查了107种阳性血液培养物和20种CSF样品(阳性和阴性),并与常规程序进行了比较。在107种阳性血液培养物中,90.7%(97/107)表现出单微生物生长,而9.3%(10/107)表现出多微生物生长。 FilmArray BCID面板覆盖了本研究中发现的89.3%(25/28)细菌和100%(2/2)酵母,并准确识别了所有细菌。从20份回顾性CSF中,在9个阳性样本中有6种不同确定细菌种类。鉴定结果的差异为25%(5/20),灵敏度低至50%(95%CI为15.7%至84.3%)。我们的研究证实FilmArray BCID板是一种快速,易于操作的PCR系统在阳性血液培养中表现良好,没有革兰氏染色结果。但是,我们的结果还表明,由于灵敏度低,该系统不能用于直接CSF测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号