摘要

This paper presents the evaluation of novel electrodes for surface electromyography (sEMG) measurements. The electrodes are based on the mixture of carbon powder, quaternary salt, and viscoelastic polymeric adhesive (carbon/salt/adhesive or simply CSA), which when combined, provide the unique advantages of having longer (theoretically infinite) shelf life and potentially lower cost than Ag/AgCl hydrogel electrodes, consistent with FLEXcon’s Patent #8 673 184. The 20 subjects were recruited to collect simultaneous recordings of sEMG signals using Ag/AgCl and CSA electrodes, side-by-side on triceps brachii, tibial anterior muscles, biceps brachii, and quadriceps femoris. Although CSA sEMG electrodes showed higher electrode-skin contact impedance for the frequency range of 4 Hz–2 kHz, no significant differences were found in the signals’ amplitude between the two electrodes either during relaxation or contraction stages. Furthermore, correlations of the computed linear envelopes (>0.91), rms value envelopes (>0.91), and power spectral densities (>0.95) of the signals were found to be high between the two media. Detected ON- and OFF-times of contraction were also highly correlated (>0.9) and interchangeable (ON-time: bias = −0.02, variance = 0.11; OFF-time: bias = −0.04, variance = 0.23) between the two media. However, CSA sEMG electrodes exhibited a significantly better response to noise (38.3 ± 10.6 dB versus 32.7 ± 15.6 dB) and motion artifacts (24.1 ± 12.1 dB versus 16.6 ± 8.52 dB), and a significantly lower spectral deformation (1.32 ± 0.2 versus 1.46 ± 0.4). Ag/AgCl electrodes showed a significantly more peaked and sensitive response to EMG amplitude (67.9 ± 13.9 dB versus 65.4 ± 14.6 dB). Given no significant differences in many of the measures described earlier and the fact that CSA electrodes have an infinite shelf-life are potentially lower cost, and are more resistant to motion artifacts, the new electrodes provide an attractive alternative to Ag/AgCl electrodes for sEMG measurements.
机译:本文介绍了用于表面肌电图(sEMG)测量的新型电极的评估。电极基于碳粉,季盐和粘弹性聚合物胶粘剂(碳/盐/胶粘剂或简单地为CSA)的混合物,将它们结合使用时具有独特的优势,即具有更长的(理论上是无限的)保质期和可能更低的成本与Ag / AgCl水凝胶电极相比,符合FLEXcon的专利号8673184。招募了20名受试者,使用Ag / AgCl和CSA电极,肱三头肌,胫骨前肌,二头肌并排同时收集sEMG信号记录。肱和股四头肌。尽管CSA sEMG电极在4 Hz–2 kHz的频率范围内显示出较高的电极-皮肤接触阻抗,但是在松弛或收缩阶段,两个电极之间的信号幅度没有发现明显差异。此外,发现两种介质之间的信号线性包络(> 0.91),均方根值包络(> 0.91)和功率谱密度(> 0.95)的相关性很高。两种介质之间检测到的收缩的开启和关闭时间也高度相关(> 0.9),并且可以互换使用(开启时间:偏差= -0.02,方差= 0.11;关闭时间:偏差= -0.04,方差= 0.23) 。然而,CSA sEMG电极对噪声(38.3±10.6 dB对32.7±15.6 dB)和运动伪影(24.1±12.1 dB对16.6±8.52 dB)表现出明显更好的响应,并且光谱变形也显着降低(1.32±0.2对1.46,对±0.4)。 Ag / AgCl电极对EMG振幅表现出明显更高的峰值和敏感响应(67.9±13.9 dB对65.4±14.6 dB)。鉴于先前描述的许多措施没有显着差异,并且CSA电极具有无限的保存期限这一事实潜在地降低了成本,并且更能抵抗运动伪影,因此新电极为sEMG提供了Ag / AgCl电极的诱人替代品测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号