Primary Stability Optimization by Using Fixtures with Different Thread Depth According To Bone Density: A Clinical Prospective Study on Early Loaded Implants

机译:通过根据骨密度使用不同螺纹深度的固定装置来优化主稳定性:早期负重种植体的临床前瞻性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Macro- and micro-geometry are among the factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to test a protocol for early loading by controlling implant stability with the selection of fixtures with different thread depth according to the bone density of the implant site. >Materials and Methods: Patients needing implant therapy for fixed prosthetic rehabilitation were treated by inserting fixtures with four different thread diameters, selected based on clinical assessment of bone quality at placement (D1, D2, D3, and D4, according to Misch classification). Final insertion torque (IT) and implant stability quotient (ISQ) were recorded at baseline and ISQ measurements repeated after one, two, three, and four weeks. At the three-week measurement (four weeks after implant replacement), implants with ISQ > 70 Ncm were functionally loaded with provisional restorations. Marginal bone level was radiographically measured 12 months after implant insertion. >Results: Fourteen patients were treated with the insertion of forty implants: Among them, 39 implants showing ISQ > 70 after 3 weeks of healing were loaded with provisional restoration. Mean IT value was 82.3 ± 33.2 Ncm and varied between the four different types of bone (107.2 ± 35.6 Ncm, 74.7 ± 14.0 Ncm, 76.5 ± 31.1 Ncm, and 55.2 ± 22.6 Ncm in D1, D2, D3, and D4 bone, respectively). Results showed significant differences except between D2 and D3 bone types. Mean ISQ at baseline was 79.3 ± 4.3 and values in D1, D2, D3, and D4 bone were 81.9 ± 2.0, 81.1 ± 1.0, 78.3 ± 3.7, and 73.2 ± 4.9, respectively. Results showed significant differences except between D1 and D2 bone types. IT and ISQ showed a significant positive correlation when analyzing the entire sample (p = 0.0002) and D4 bone type (p = 0.0008). The correlation between IT and ISQ was not significant when considering D1, D2, and D3 types (p = 0.28; p = 0.31; p = 0.16, respectively). ISQ values showed a slight drop at three weeks for D1, D2, and D3 bone while remaining almost unchanged in D4 bone. At 12-month follow-up, all implants (39 early loading, 1 conventional loading) had satisfactory function, showing an average marginal bone loss of 0.12 ± 0.12 mm, when compared to baseline levels. Conclusion: Matching implant macro-geometry to bone density can lead to adequate implant stability both in hard and soft bone. High primary stability and limited implant stability loss during the first month of healing could allow the application of early loading protocols with predictable clinical outcomes.
机译:>背景:宏观和微观几何是影响植入物稳定性并可能确定加载方案的因素。这项研究的目的是通过根据植入部位的骨密度选择具有不同螺纹深度的固定装置来控制植入物的稳定性,从而测试早期加载的方案。 >材料和方法:需要对植入物进行固定修复的患者,通过插入具有四个不同螺纹直径的固定装置进行治疗,这些固定装置是根据临床对骨质量的评估(D1,D2,D3和D4,根据Misch分类)。在基线记录最终的插入扭矩(IT)和植入物稳定性商(ISQ),并在1、2、3和4周后重复进行ISQ测量。在三周的测量中(植入物更换后的四周),将ISQ> 70 Ncm的植入物在功能上加载了临时修复体。在植入物植入后12个月,通过放射照相测量边缘骨水平。 >结果: 14例患者接受了40枚植入物的植入治疗:其中,对3例愈合3周后ISQ> 70的植入物进行了临时修复。平均IT值为82.3±33.2 Ncm,并且在四种不同类型的骨之间变化(D1,D2,D3和D4骨分别为107.2±35.6 Ncm,74.7±14.0 Ncm,76.5±31.1 Ncm和55.2±22.6 Ncm )。结果显示,除了D2和D3骨骼类型外,其他均存在显着差异。基线时的平均ISQ为79.3±4.3,D1,D2,D3和D4骨骼的值分别为81.9±2.0、81.1±1.0、78.3±3.7和73.2±4.9。结果显示,除了D1和D2骨类型之间存在显着差异。分析整个样本(p = 0.0002)和D4骨类型(p = 0.0008)时,IT和ISQ呈显着正相关。当考虑D1,D2和D3类型时,IT和ISQ之间的相关性并不显着(分别为p = 0.28; p = 0.31; p = 0.16)。 ISQ值显示D1,D2和D3骨在三周内略有下降,而D4骨几乎保持不变。在12个月的随访中,所有植入物(39个早期负荷,1个常规负荷)均具有令人满意的功能,与基线水平相比,平均边缘骨质损失为0.12±0.12 mm。结论:使植入物宏观几何形状与骨密度相匹配可以在硬骨和软骨中均具有足够的植入物稳定性。在康复的第一个月内,较高的主要稳定性和有限的植入物稳定性损失可允许采用可预测的临床结果的早期负荷方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号