首页> 美国卫生研究院文献>Materials >Push-Out Bond Strength and SEM Evaluation in Roots Filled with Two Different Techniques Using New and Conventional Sealers
【2h】

Push-Out Bond Strength and SEM Evaluation in Roots Filled with Two Different Techniques Using New and Conventional Sealers

机译:使用新的和传统的密封剂填充两种不同技术的牙根的推出强度和SEM评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

The aim of this study was to evaluate the influence of calcium-silicate-based sealer (Endosequence-BC-Sealer) in roots, filled with thermo-plasticized injectable technique aided by Calamus-Flow-Delivery-System, on bond strength to radicular dentin, in comparison with conventional epoxy-resin-based sealer (AH-Plus) along with cold-lateral-compaction technique. Root canals of mandibular-premolar teeth (n = 80) were instrumented using Protaper Universal rotary files and were randomly divided into four experimental groups (n = 20) as follows: (1) AH-Plus + cold-lateral-compaction technique; (2) Endosequence-BC-Sealer + cold-lateral-compaction technique; (3) AH-Plus + thermo-plasticized injectable technique; and (4) Endosequence-BC-Sealer + thermo-plasticized injectable technique. Horizontal disc shaped samples from each group (n = 60/group) were obtained and push-out bond strength testing was performed at a cross-head speed of 0.5 mm/min. Data were analyzed statistically using nonparametric Kruskal-Wallis analysis and Mann-Whitney test (p < 0.001). The statistical analysis revealed a significant difference amongst the groups (p < 0.001). The highest bond strength values were found in group 1 compared with all the other experimental groups (p < 0.001), whereas the lowest bond strength values were found in group 4 (p < 0.001). It was concluded that thermo-plasticized injectable technique with Calamus-Flow-Delivery-System lowered the bond strengths of the sealers, especially Endosequence-BC-Sealer. Therefore, this technique is not recommended to calcium-silicate-based sealers. Further studies are needed to confirm the findings of this study.
机译:这项研究的目的是评估在根管中填充硅酸钙基封闭剂(Endosequence-BC-Sealer)对根部与牙本质的结合强度的影响,其中根部填充有热塑注射技术(由Calamus-Flow-Delivery-System辅助)与传统的基于环氧树脂的密封剂(AH-Plus)以及冷侧压技术相比。使用Protaper Universal旋转锉对下颌前磨牙的根管(n = 80)进行检测,并随机分为以下四个实验组(n = 20):(1)AH-Plus +冷侧压实技术; (2)内序列-BC-Sealer +冷侧压实技术; (3)AH-Plus +热塑注射技术; (4)Endosequence-BC-Sealer +热塑注射技术。从每组(n = 60 /组)中获取水平的盘状样品,并以0.5 mm / min的十字头速度进行推出粘结强度测试。使用非参数Kruskal-Wallis分析和Mann-Whitney检验对数据进行统计学分析(p <0.001)。统计分析表明各组之间存在显着差异(p <0.001)。与其他所有实验组相比,第1组的粘结强度最高(p <0.001),第4组的粘结强度最低(p <0.001)。结论是,采用Calamus-Flow-Delivery-System的热塑注射技术降低了封口剂的粘合强度,尤其是Endosequence-BC-Sealer。因此,不建议将该技术推荐给硅酸钙基密封剂。需要进一步的研究以确认这项研究的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号