Temporal Trends of Malondialdehyde in Stored Human Plasma

机译:人体血浆中丙二醛的时间趋势

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Malondialdehyde (MDA) is widely used as oxidative stress biomarker in biomedical research. Plasma is stored in deep freezers generally till analysis. Effect of such storage on MDA values, which may be variable and prolong, was incidentally observed in the ongoing study which is to estimate oxidative stress with oral iron. Plasma from blood samples of pregnant women (20–30 years age) in third trimester of singleton pregnancy (n = 139), consuming oral iron tablets was stored at −20 °C with intention of MDA estimation, as soon as possible. However logistic problems led this storage for prolonged and variable period (1–708 days). When values of MDA estimated using “Ohkawa” 79 method and readings were plotted against time to check the temporal effect, it showed a hyperbolic curve. Standard deviation (SD) was lowest when samples were tested within 3 weeks time. The samples analyzed within 3 weeks had mean ± SD value of 31.59 ± 26.11 μmol/L, while 123.7 ± 93.97 and 366.5 ± 189.8 μmol/L for samples stored for 1–3 and 4 months to 1 year respectively. Mean ± SD were 539.9 ± 196.8 in the samples store for more than a year. Rate of change in values was also lowest (0.0433 μmol/L/day) in the samples tested within first 3 weeks, which rose to 1.2 μmol/L/day during 3 month’s storage. This rate peaked at storage of 120 days (1.87 μmol/L/day) and fell to 0.502 μmol/L/day in the second year of storage. It is concluded that at −20 °C, only 3 weeks of storage time should be considered valid for fairly acceptable stability in MDA values.
机译:丙二醛(MDA)在生物医学研究中被广泛用作氧化应激生物标志物。血浆通常保存在深冷柜中直至分析。在正在进行的研究中偶然地观察到了这种贮存对MDA值的影响,该MDA值可能是可变的并且是延长的,该研究是估计口服铁的氧化应激。单胎妊娠晚期(n = 139)孕妇(20-30岁)的血液样本中的血浆,消耗的口服铁片应尽快保存在-20°C下以MDA估算。但是,物流问题导致这种存储时间延长且变化多端(1–708天)。当使用“ Ohkawa” 79方法估算的MDA值和读数相对于时间作图以检查时间效应时,显示为双曲线。在3周内测试样品时,标准偏差(SD)最低。在3周内分析的样品的平均SD值为31.59±26.11μmol/ L,而对于1-3个月和4个月至1年的样品分别为123.7±93.97和366.5±189.8μmol/ L。样本存储超过一年的平均值±SD为539.9±196.8。在前三个星期内测试的样品中,值的变化率也最低(0.0433μmol/ L /天),在存储三个月内上升到1.2μmol/ L /天。该速率在存储120天(1.87μmol/ L /天)时达到峰值,而在存储第二年降至0.502μmol/ L /天。结论是,在-20°C下,对于MDA值相当可接受的稳定性,应仅认为3周的存储时间有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号