首页> 美国卫生研究院文献>International Journal of Analytical Chemistry >Determination of Trace Antimony (III) in Water Samples with Single Drop Microextraction Using BPHA-C4mimPF6 System Followed by Graphite Furnace Atomic Absorption Spectrometry
【2h】

Determination of Trace Antimony (III) in Water Samples with Single Drop Microextraction Using BPHA-C4mimPF6 System Followed by Graphite Furnace Atomic Absorption Spectrometry

机译:BPHA- C4mim PF6系统-石墨炉原子吸收光谱法单滴微萃取测定水样中痕量锑(III)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new sensitive method for antimony (III) determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed by using N-benzoyl-N-phenylhydroxylamine (BPHA) and 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) single drop microextraction. The single drop microextraction (SDMM) system is more competitive compared with other traditional extraction methods. Under the optimized conditions, the limit of detection (signal-to-noise ratio is 3) and the enrichment factor of antimony (III) are 0.01 μg·L−1 and 112, respectively. The relative standard deviation of the 0.5 μg·L−1 antimony (III) is 4.2% (n=6). The proposed method is rather sensitive to determinate trace antimony (III) in water.
机译:N-苯甲酰基-N-苯基羟胺(BPHA)和1-丁基-3-甲基咪唑六氟磷酸盐([C4mim] [PF6] )单滴微萃取。与其他传统提取方法相比,单滴微提取(SDMM)系统更具竞争力。在最佳条件下,检测限(信噪比为3)和锑(III)的富集系数分别为0.01μg·L -1 和112。 0.5μg·L -1 锑(III)的相对标准偏差为4.2%(n = 6)。所提出的方法对测定水中的痕量锑非常敏感。