A simplified lateral-flow assay for the detection of antibodies to HIV using magnetic-bead conjugates and multibranched peptides from both HIV-1 and HIV-2 was developed. Magnetic immunochromatography testing (MICT) uses a standard lateral-flow platform that incorporates magnetic-bead conjugates for quantitative measurement of the magnetic field distortion associated with the bound magnetic conjugate (reported as adjusted relative magnetic units [MAR]). The results of the optimized MICT assay were compared to standard enzyme immunoassay (EIA) and Western blotting (WB) results using a blinded 649-member panel of specimens from the United States, Cameroon, and West Africa. The panel was comprised of samples from individuals infected with various HIV-1 subtypes (n = 234) or HIV-2 (n = 65) and HIV-seronegative specimens (n = 350). Additionally, 13 HIV-1 seroconversion panels (total specimens = 85), a worldwide panel containing seven of the major circulating HIV-1 subtypes (n = 18), an HIV-2 panel, an HIV-1/HIV-2 mixed panel, and 100 prospective specimens were tested with completely concordant results. Assay reproducibility (observed MAR) for both intra- and interrun testing was excellent, with coefficients of variation of <12%. MICT can provide a rapid, low-cost method of determining HIV antibody status requiring no subjective interpretations.
机译:开发了一种简化的侧流测定法,该方法使用磁珠结合物和来自HIV-1和HIV-2的多支肽来检测HIV抗体。磁免疫色谱测试(MICT)使用标准的横向流动平台,该平台结合了磁珠结合物,用于定量测量与结合的磁性结合物相关的磁场畸变(报告为调整后的相对磁性单位[MAR])。使用来自美国,喀麦隆和西非的649名盲人样本,将优化的MICT分析的结果与标准酶免疫分析(EIA)和蛋白质印迹(WB)的结果进行比较。该小组由感染各种HIV-1亚型(n = 234)或HIV-2(n = 65)的个体的样品和HIV血清阴性标本(n = 350)组成。此外,还有13个HIV-1血清转化专家组(标本总数= 85),一个全球性专家组,其中包含7种主要的循环HIV-1亚型(n = 18),一个HIV-2专家组,一个HIV-1 / HIV-2混合专家组,并对100个预期样本进行了测试,结果完全一致。批内和批间测试的重现性(观察到的MAR)均非常好,变异系数<12%。 MICT可以提供一种快速,低成本的方法来确定HIV抗体状态,不需要主观解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号