首页> 美国卫生研究院文献>Clinical and Diagnostic Laboratory Immunology >Inter- and intrainstitutional evaluation of automated volumetric capillary cytometry for the quantitation of CD4- and CD8-positive T lymphocytes in the peripheral blood of persons infected with human immunodeficiency virus. Site Investigators and the NIAID New CD4 Technologies Focus Group.
【2h】

Inter- and intrainstitutional evaluation of automated volumetric capillary cytometry for the quantitation of CD4- and CD8-positive T lymphocytes in the peripheral blood of persons infected with human immunodeficiency virus. Site Investigators and the NIAID New CD4 Technologies Focus Group.

机译:定量和定量评估自动容积毛细管细胞术定量感染人免疫缺陷病毒的人外周血中CD4和CD8阳性T淋巴细胞。站点调查员和NIAID新CD4技术焦点小组。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Volumetric capillary cytometry (VCC) is a new technology that involves the detection and enumeration of dually fluorochrome-labeled cells in a precise volume. We compared the accuracy and precision of VCC with the accuracy and precision of flow cytometry and hematology (F&H) for the measurement of the absolute numbers of CD4 and CD8 T cells in the whole blood of patients infected with human immunodeficiency virus. Five laboratories, each with a different F&H system and certified by the National institute of Allergy and Infectious Diseases flow cytometry proficiency testing program, were shipped aliquots of the same samples from a central site in addition to procuring samples locally. In general, the VCC technology generated CD4 and CD8 T-cell counts which were lower than those obtained with F&H. Intralaboratory variability of replicate CD4 T-cell determinations was similar for both technologies except in the local samples with CD4 counts less than 200/microliters, where the VCC variability was higher than the F&H variability. Interlaboratory variability on replicate CD4 T-cell counts made by VCC was significantly less than that when counts were made by F&H. The VCC instrument has automated CD4 and CD8 T-cell enumeration in whole blood and has consolidated the process to a single platform. Its performance in this evaluation indicates that it may represent a viable alternative to F&H for obtaining absolute T-cell subset counts.
机译:体积毛细管细胞术(VCC)是一项新技术,涉及以精确体积检测和枚举双荧光染料标记的细胞。我们将VCC的准确性和精密度与流式细胞术和血液学(F&H)的准确性和精密度进行了比较,以测量感染了人类免疫缺陷病毒的患者全血中CD4和CD8 T细胞的绝对数量。五个实验室,每个实验室都有不同的F&H系统,并获得了美国国家过敏和传染病研究所流式细胞仪能力测试计划的认证,除了从当地采购样品外,还从中心地点运送了相同样品的等分试样。通常,VCC技术产生的CD4和CD8 T细胞计数低于F&H获得的CD4和CD8 T细胞计数。两种技术的重复CD4 T细胞测定的实验室内变异性相似,不同之处在于CD4计数低于200 /微升的本地样本中VCC变异性高于F&H变异性。 VCC复制的CD4 T细胞计数的实验室间变异性显着小于F&H计数的实验室间变异性。 VCC仪器具有自动全血CD4和CD8 T细胞计数功能,并将该过程整合为一个平台。它在该评估中的性能表明,它可以代表F&H以获得可行的T细胞亚群绝对计数。