首页> 美国卫生研究院文献>Canadian Journal of Comparative Medicine >Cortisol and free thyroxine determination by time-resolved fluorometry in canine serum
【2h】

Cortisol and free thyroxine determination by time-resolved fluorometry in canine serum

机译:时间分辨荧光法测定犬血清中的皮质醇和游离甲状腺素

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Validation for canine serum of 2 commercially available time-resolved fluoroimmunoassays (TR-FIAs) designed for analysis of cortisol and free thyroxine (fT4) in human serum was carried out. Included was the study of interference by hemolysis, lipemia, and bilirubinemia. With the dissociation enhancement lanthanide fluoroimmunoassay kits, the intraassay coefficient of variation (CV) ranged from 6.4% to 8.7% for cortisol and from 5.3% to 9.8% for fT4; the interassay CVs ranged from 5.8% to 10.8% and from 3.9% to 14.1%, respectively. Accuracy was evaluated by comparing cortisol and fT4 results obtained with TR-FIA and those obtained with a validated enzyme-linked immunosorbent assay (ELISA) and an equilibrium dialysis (ED) assay, respectively. The regression equations obtained were y = 0.57x + 1.18 (r2 = 0.90) for cortisol and y = 0.87x + 0.82 (r2 = 0.93) for fT4. The limits of detection for cortisol and fT4 were 4.84 nmol/L and 2.68 pmol/L, respectively. The results of adrenocorticotropin-stimulation and dexamethasone-suppression tests were similar to those published previously; likewise, serial dilution of a canine serum sample with a high cortisol content demonstrated that the TR-FIA was immunologically specific. Serial dilution of a serum sample with a high fT4 concentration showed a methodologic bias, a dependence on serum binding capacity, which indicates that the results obtained with this method should be interpreted with caution. Finally, hemolysis and lipemia significantly interfered with cortisol and fT4 measurements, whereas bilirubinemia did not affect the results.
机译:对两种用于分析人血清中的皮质醇和游离甲状腺素(fT4)的市售时间分辨荧光免疫测定法(TR-FIA)的犬血清进行了验证。包括溶血,血脂和胆红素血症干扰的研究。使用解离增强镧系荧光免疫测定试剂盒,皮质醇的测定内变异系数(CV)为6.4%至8.7%,fT4的测定内变异系数为5.3%至9.8%。批间CV的范围分别为5.8%至10.8%和3.9%至14.1%。通过比较通过TR-FIA获得的皮质醇和fT4结果以及通过经过验证的酶联免疫吸附测定(ELISA)和平衡透析(ED)测定获得的结果来评估准确性。对于皮质醇,获得的回归方程为y = 0.57x + 1.18(r 2 = 0.90),对于fT4,y = 0.87x + 0.82(r 2 = 0.93)。皮质醇和fT4的检出限分别为4.84 nmol / L和2.68 pmol / L。促肾上腺皮质激素刺激和地塞米松抑制试验的结果与以前发表的结果相似。同样,对具有高皮质醇含量的犬血清样品进行连续稀释表明TR-FIA具有免疫学特异性。 fT4浓度高的血清样品的连续稀释显示出方法学上的偏倚,取决于血清结合能力,这表明用这种方法获得的结果应谨慎解释。最后,溶血和血脂明显干扰了皮质醇和fT4的测量,而胆红素血症并未影响结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号