A field study of 89 refrigerator repairmen was carried out to ascertain whether occupational exposure to fluorocarbons induces cardiac arrhythmia. The concentrations of fluorocarbons in the breathing zones and the heart activity were recorded simultaneously. Most cooling systems contained FC 12 or FC 22. The highest level recorded in one minute was 14,000 ppm and the highest time weighted level during eight hours was 280 ppm. Two types of arrhythmia were recorded, ectopic beats and sudden bradycardia. A within subject comparison design was applied and the main parameter was the difference in arrhythmia frequencies between exposed and unexposed periods. No appreciable differences between exposed and unexposed periods and no consistent dose effect relations were observed, although subjects in the medium exposure category showed a difference of borderline significance (Wilcoxon's test: p = 0.05, one tailed). The frequencies of arrhythmia when unexposed were somewhat higher than previously reported. Misclassification of the exposure and the possible confounding effect of physical workload and psychological strain may have obscured a causal relation and therefore a minor effect cannot be ruled out. The results do not support the notion that fluorocarbons induce cardiac arrhythmia in occupationally exposed refrigerator repairmen.
机译:进行了89位冰箱维修人员的现场研究,以确定职业性接触碳氟化合物是否会引起心律不齐。同时记录呼吸区中的碳氟化合物浓度和心脏活动。大多数冷却系统包含FC 12或FC22。一分钟内记录的最高水平为14,000 ppm,八小时内最高时间加权水平为280 ppm。记录了两种类型的心律失常,异位搏动和心动过缓。应用受试者内部比较设计,主要参数是暴露和未暴露时期之间心律失常频率的差异。尽管中度暴露类别的受试者表现出临界显着性差异(Wilcoxon's检验:p = 0.05,一条尾巴),但未观察到暴露时期和未暴​​露时期之间的可观差异,也未观察到一致的剂量效应关系。未暴露时心律失常的频率比以前报道的要高。暴露的错误分类以及身体工作量和心理压力的可能混杂影响可能掩盖了因果关系,因此不能排除轻微影响。该结果不支持碳氟化合物在职业暴露的冰箱维修人员中导致心律不齐的观念。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号