Chest radiographs of 661 British electric-arc welders have been examined by three film readers experienced in the radiology of pneumoconiosis. About 7% of the welders showed signs of small rounded opacities of category 0/1 or greater. No definite evidence of large opacities (Progressive Massive Fibrosis) was seen. The prevalence of chest abnormalities other than pneumoconiosis was 7%. A clear association between prevalence of small rounded opacities of category 0/1 or greater and years of exposure to fumes was established, although few signs of severe grades of simple pneumoconiosis were seen.
机译:由三名在尘肺病放射学方面有经验的电影读者检查了661台英国电弧焊机的胸部X光片。大约7%的焊工显示出0/1或更高等级的小浑圆浑浊的迹象。没有发现大混浊的明确证据(进行性大规模纤维化)。除尘肺病外,胸部异常的患病率为7%。尽管很少见到严重程度的单纯性尘肺病的迹象,但0/1或更高类别的小圆形浑浊的患病率与暴露年限之间存在明确的关联。