Recognition that vinyl chloride could be hepatotoxic led to a survey of workers to determine whether changes had been induced by past exposure, and to evaluate standard liver function tests as monitors of early liver abnormalities. Standard liver function tests were found to be unsuitable for the detection of such abnormalities in the population at risk. Of 487 workers examined, 102 (20-9%) had abnormalities on initial testing but only two were finally shown to have portal hypertension; in both cases, thrombocytopaenia provided the first diagnostic evidence since liver function tests were normal. Furthermore, 40 (35-7%) of 112 control subjects had initial test abnormalities. A sample of 19 workers with various exposures to vinyl chloride monomer were examined blind by greyscale ultrasonography. Five with minimal or no exposure were confirmed as normal but 12 of the remainder had abnormalities. These consisted of an enlarged portal vein (seven instances), splenomegaly (eight), and changes in hepatic texture (seven). Five of these 12 cases had previously been considered normal. It was concluded that greyscale ultrasonography had many advantages over standard methods for screening workers exposed to hepatotoxic chemicals, and should be the subject of a large scale evaluation.
机译:认识到氯乙烯可能具有肝毒性,导致对工人进行了一项调查,以确定过去的暴露是否引起了变化,并评估了标准肝功能测试作为早期肝异常的监测者。发现标准肝功能测试不适合检测处于危险中的人群中的此类异常。在接受检查的487名工人中,有102名(20-9%)在初次检查时出现异常,但最终只有2名显示出门静脉高压;在这两种情况下,由于肝功能检查正常,血小板减少症提供了首个诊断依据。此外,在112名对照受试者中,有40名(35-7%)有初始测试异常。通过灰度超声检查对19名不同程度地接触氯乙烯单体的工人进行了抽样检查。 5例暴露极少或没有暴露被确认为正常,但其余12例有异常。其中包括门静脉增大(七例),脾肿大(八例)和肝纹理变化(七例)。这12例病例中有5例以前被认为是正常的。得出的结论是,与超声筛查暴露于肝毒性化学物质的工人的标准方法相比,灰度超声检查具有许多优势,应作为大规模评估的对象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号