首页> 美国卫生研究院文献>British Heart Journal >Imaging of thrombi and assessment of left atrial appendage function: a prospective study comparing transthoracic and transoesophageal echocardiography
【2h】

Imaging of thrombi and assessment of left atrial appendage function: a prospective study comparing transthoracic and transoesophageal echocardiography

机译:血栓成像和左心耳功能评估:一项比较经胸和经食道超声心动图的前瞻性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective—To compare the value of current transthoracic echocardiographic systems and transoesophageal echocardiography for assessing left atrial appendage function and imaging thrombi.
Design—Single blind prospective study. Patients were first investigated by transthoracic echocardiography and thereafter by a second investigator using transoesophageal echocardiography. The feasibility of imaging the left atrial appendage, recording its velocities, and identifying thrombi within the appendage were determined by both methods.
Patients—117 consecutive patients with a stroke or transient neurological deficit.
Setting—Tertiary cardiac and neurological care centre.
Results—Imaging of the complete appendage was feasible in 75% of the patients by transthoracic echocardiography and in 95% by transoesophageal echocardiography. Both methods were concordant for the detection of thrombi in 10 cases. Transoesophageal echocardiography revealed two additional thrombi. In one of these patients, transthoracic echocardiography was not feasible and in the other the thrombus had been missed by transthoracic examination. In patients with adequate transthoracic echogenicity, the specificity and sensitivity of detecting left atrial appendage thrombi were 100% and 91%, respectively. Recording of left atrial appendage velocities by transthoracic echocardiography was feasible in 69% of cases. None of the patients with a velocity > 0.3 m/s had left atrial appendage thrombi. In the one patient in whom transthoracic echocardiographic evaluation missed a left atrial appendage thrombus, the peak emptying velocity of the left atrial appendage was 0.25 m/s.
Conclusions—A new generation echocardiographic system allows for the transthoracic detection of left atrial appendage thrombi and accurate determination of left atrial appendage function in most patients with a neurological deficit.

Keywords: echocardiography; left atrial appendage thrombi; stroke; thromboembolism
机译:目的—比较目前经胸超声心动图和经食道超声心动图在评估左心耳功能和成像血栓方面的价值。
设计—单盲前瞻性研究。首先通过经胸超声心动图检查患者,然后由第二位研究者使用经食道超声心动图检查患者。两种方法均确定了对左心耳成像,记录其速度并确定耳内血栓的可行性。
患者-117名连续中风或短暂性神经功能缺损的患者。
设置-第三心脏和神经科护理中心。
结果-经胸超声心动图检查对75%的患者和经食道超声心动图检查对95%的患者进行完全附件的成像是可行的。两种方法均能在10例病例中检测出血栓。经食道超声心动图检查发现另外两个血栓。在其中一名患者中,经胸超声心动图检查不可行,而在另一例中,经胸检查漏诊了血栓。在具有足够的经胸回声能力的患者中,检测左心耳附件血栓的特异性和敏感性分别为100%和91%。经胸超声心动图记录左心耳速度在69%的病例中是可行的。速度> 0.3 m / s的患者均无左心耳血栓。在经胸超声心动图评估漏诊左心耳血栓的一名患者中,左心耳的排空峰值速度为0.25m / s。
结论—新一代超声心动图系统可以经胸腔检测左心房多数神经系统功能不全患者的附件血栓形成和左心耳附件功能的准确测定。