Objective—To compare vessel, lumen, and plaque volumes in atherosclerotic coronary lesions with inadequate compensatory enlargement versus lesions with adequate compensatory enlargement.
Design—35 angiographically significant coronary lesions were examined by intravascular ultrasound (IVUS) during motorised transducer pullback. Segments 20 mm in length were analysed using a validated automated three dimensional analysis system. IVUS was used to classify lesions as having inadequate (group I) or adequate (group II) compensatory enlargement.
Results—There was no significant difference in quantitative angiographic measurements and the IVUS minimum lumen cross sectional area between groups I (n = 15) and II (n = 20). In group I, the vessel cross sectional area was 13.3 (3.0) mm2 at the lesion site and 14.4 (3.6) mm2 at the distal reference (p < 0.01), whereas in group II it was 17.5 (5.6) mm2 at the lesion site and 14.0 (6.0) mm2 at the distal reference (p < 0.001). Vessel and plaque cross sectional areas were significantly smaller in group I than in group II (13.3 (3.0) v 17.5 (5.6) mm2, p < 0.01; and 10.9 (2.8) v 15.2 (4.9) mm2, p < 0.005). Similarly, vessel and plaque volume were smaller in group I (291.0 (61.0) v 353.7 (110.0) mm3, and 177.5 (48.4) v 228.0 (92.8) mm3, p < 0.05 for both). Lumen areas and volumes were similar.
Conclusions—In lesions with inadequate compensatory enlargement, both vessel and plaque volume appear to be smaller than in lesions with adequate compensatory enlargement.

Keywords: intravascular ultrasound;  ultrasonics;  remodelling;  coronary artery disease
机译:目的—比较代偿性扩大不足的动脉粥样硬化病变与代偿性适当扩大的病变中血管,管腔和斑块的体积。
设计—在电动换能器回撤期间,通过血管内超声(IVUS)检查了35例具有血管造影显着性的冠状动脉病变。使用经过验证的自动化三维分析系统分析长度为20毫米的线段。 IVUS用于将病变分类为补偿不足(I组)或适当(II组)。
结果— I组之间定量血管造影测量和IVUS最小管腔横截面积无显着差异。 = 15)和II(n = 20)。在第一组中,病变部位的血管横截面积为13.3(3.0)mm 2 ,远端参考为14.4(3.6)mm 2 (p <0.01) ,而在第二组中,病变部位为17.5(5.6)mm 2 ,远端参考为14.0(6.0)mm 2 (p <0.001)。 I组的血管和斑块横截面面积明显小于II组(13.3(3.0)v 17.5(5.6)mm 2 ,p <0.01;和10.9(2.8)v 15.2(4.9) mm 2 ,p <0.005)。同样,第一组的血管和斑块体积较小(291.0(61.0)v 353.7(110.0)mm 3 ,和177.5(48.4)v 228.0(92.8)mm 3 ,两者的p <0.05)。管腔面积和体积相似。
结论—在代偿性扩大不足的病变中,血管和斑块的体积似乎均小于代偿性充分扩大的病变。