首页> 美国卫生研究院文献>British Heart Journal >Transcatheter coil occlusion of residual interatrial communications after Fontan procedure
【2h】

Transcatheter coil occlusion of residual interatrial communications after Fontan procedure

机译:Fontan手术后残留患者房间通信的经导管线圈闭塞

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective—To assess the use of detachable coils as an alternative method to occlude interatrial communications after Fontan operations.
Design—Descriptive clinical study of selected patients after Fontan operation with interatrial communications inappropriate for transcatheter umbrella occlusion.
Setting—Tertiary paediatric cardiac referral centre.
Patients—Seven patients after Fontan operation with residual interatrial communications of various types producing a right to left shunt.
Interventions—Transcatheter placement of detachable coils with a diameter of 3 or 5 mm within the interatrial communication.
Results—A total of 14 coils were successfully placed within persistent patent fenestrations of the interatrial baffle, residual leaks at the suture line between the patch material and the right atrial wall, and unusual venous interatrial communications. The mean (SD) aortic oxygen saturation increased from 88 (1.1)% (range, 86-89%) to 92 (1.3)% (range, 89-93%; p < 0.001) and the mean (SD) right atrial pressure rose from 9.7 (2) mm Hg (range, 6-11) to 10.6 (2.4) mm Hg (range, 6-13; p < 0.05) after coil implantation. In five patients, complete obliteration of the interatrial shunt was shown by angiography after coil implantation. At a mean (SD) follow up of 10 (4) months (range, 3-15) a residual interatrial shunt was detected by Doppler colour echocardiography in only one patient, and oxygen saturations ranged from 90% to 95% (mean, 92%). There were no late coil embolisations, thromboembolic events, or haemolysis in any patient.
Conclusions—Detachable coils can be used successfully to occlude residual interatrial communications after the Fontan procedure. In selected cases, in whom intended transcatheter umbrella occlusion of residual interatrial leaks is not possible, the use of detachable coils might offer a safe alternative method to eliminate interatrial right to left shunting after the Fontan procedure.

Keywords: Fontan procedure;  residual interatrial communication;  coil occlusion
机译:目的-评估在Fontan手术后使用可分离线圈作为阻塞房颤的另一种方法。
设计-在Fontan手术后对某些患者进行描述性临床研究,该研究不适合经导管伞闭塞的房颤。
设置—三级小儿心脏转诊中心。
患者—丰坦手术后有7例患者,各种类型的残留房间通信导致右向左分流。
结果-共成功地将14个线圈放置在房间隔板的永久性开窗,修补材料与右房壁之间的缝合线残留泄漏以及异常静脉房间通信中。平均(SD)主动脉血氧饱和度从88(1.1)%(范围86-89%)增加到92(1.3)%(范围89-93%; p <0.001)和平均(SD)右房压线圈植入后从9.7(2)mmHg(范围6-11)上升到10.6(2.4)mmHg(范围6-13; p <0.05)。在五例患者中,线圈植入后血管造影显示房间分流完全消失。平均(SD)随访10(4)个月(范围3-15),仅多普勒彩色超声心动图检查发现仅一名患者发生了房性分流,并且血氧饱和度范围为90%至95%(平均值92 %)。任何患者均无晚期线圈栓塞,血栓栓塞事件或溶血。
结论:可拆卸线圈可以成功地用于封堵Fontan手术后残留的房间通讯。在某些情况下,如果无法通过导管粗大地遮盖残留的心房渗漏,使用可拆卸的线圈可能会提供一种安全的替代方法,以消除Fontan手术后从右向左分流的心房。

关键词:Fontan程序;残留的房间通讯;线圈闭塞