您现在的位置:首页>美国卫生研究院文献>Biomedical Optics Express

期刊信息

  • 期刊名称:

    -

  • 刊频: Monthly
  • NLM标题: Biomed Opt Express
  • iso缩写: -
  • ISSN: -
  • 排序:
  • 显示:
  • 每页:
全选(0
<1/20>
4025条结果
  • 机译 高压纳米磷的长发光寿命的积极作用在非紧凑型无滤波器生物测定中的共振表面上
    摘要:We introduce a compact array fluorescence sensor principle that takes advantage of the long luminescence lifetimes of upconversion nanoparticles (UCNPs) to deploy a filter-free, optics-less contact geometry, advantageous for modern biochemical assays of biomolecules, pollutants or cells. Based on technologically mature CMOS chips for ∼10 kHz technical/scientific imaging, we propose a contact geometry between assayed molecules or cells and a CMOS chip that makes use of only a faceplate or direct contact, employing time-window management to reject the 975 nm excitation light of highly efficient UCNPs. The chip surface is intended to implement, in future devices, a resonant waveguide grating (RWG) to enhance excitation efficiency, aiming at the improvement of upconversion luminescence emission intensity of UCNP deposited atop of such an RWG structure. Based on mock-up experiments that assess the actual chip rejection performance, we bracket the photometric figures of merit of such a promising chip principle and predict a limit of detection around 10-100 nanoparticles.
  • 机译 使用自干扰数字全息术三维光学定位显微镜的基本精度界限
    摘要:Localization based microscopy using self-interference digital holography (SIDH) provides three-dimensional (3D) positional information about point sources with nanometer scale precision. To understand the performance limits of SIDH, here we calculate the theoretical limit to localization precision for SIDH when designed with two different configurations. One configuration creates the hologram using a plane wave and a spherical wave while the second configuration creates the hologram using two spherical waves. We further compare the calculated precision bounds to the 3D single molecule localization precision from different Point Spread Functions. SIDH results in almost constant localization precision in all three dimensions for a 20 µm thick depth of field. For high signal-to-background ratio (SBR), SIDH on average achieves better localization precision. For lower SBR values, the large size of the hologram on the detector becomes a problem, and PSF models perform better.
  • 机译 具有近红外穆勒扫描显微镜的生物组织的线性解吸成像
    摘要:Among the multitude of optical polarization contrasts that can be observed in complex biological specimens, linear diattenuation (LD) imaging has received little attention. It is indeed challenging to image LD with basic polarizing microscopes because it is often relatively small in comparison with linear retardance (LR). In addition, interpretation of LD images is not straightforward when experiments are conducted in the visible range because LD can be produced by both dichroism and anisotropic scattering. Mueller polarimetry is a powerful implementation of polarization sensing able to differentiate and measure the anisotropies of specimens. In this article, near infrared transmission Mueller scanning microscopy is used to image LD in thin biological specimen sections made of various proteins with unprecedented resolution and sensitivity. The near infrared spectral range makes it possible to lower the contribution of dichroism to the total linear diattenuation in order to highlight anisotropic scattering. Pixel-by-pixel comparison of LD images with LR and multiphoton images demonstrates that LD is produced by under-resolved structures that are not revealed by other means, notably within the sarcomere of skeletal muscles. LD microscopy appears as a powerful tool to provide new insights into the macro-molecular organization of biological specimens at the sub-microscopic scale without labelling.
  • 机译 光学相干断层造影血管造影图像产生和去噪的最大后验信号恢复
    摘要:Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed over time and used to compute OCTA image data. OCTA data are prone to noise and artifacts caused by variations in flow speed and patient movement. We propose a novel iterative maximum a posteriori signal recovery algorithm in order to generate OCTA volumes with reduced noise and increased image quality. This algorithm is based on previous work on probabilistic OCTA signal models and maximum likelihood estimates. Reconstruction results using total variation minimization and wavelet shrinkage for regularization were compared against an OCTA ground truth volume, merged from six co-registered single OCTA volumes. The results show a significant improvement in peak signal-to-noise ratio and structural similarity. The presented algorithm brings together OCTA image generation and Bayesian statistics and can be developed into new OCTA image generation and denoising algorithms.
  • 机译 人脑胶质瘤和完整组织的太赫兹介电光谱
    摘要:Terahertz (THz) technology offers novel opportunities in the intraoperative neurodiagnosis. Recently, the significant progress was achieved in the study of brain gliomas and intact tissues, highlighting a potential for THz technology in the intraoperative delineation of tumor margins. However, a lack of physical models describing the THz dielectric permittivity of healthy and pathological brain tissues restrains the further progress in this field. In the present work, the ex vivo THz dielectric response of human brain tissues was analyzed using relaxation models of complex dielectric permittivity. Dielectric response of tissues was parametrized by a pair of the Debye relaxators and a pair of the overdamped-oscillators – namely, the double-Debye (DD) and double-overdamped-oscillator (DO) models. Both models accurately reproduce the experimental curves for the intact tissues and the WHO Grades I–IV gliomas. While the DD model is more common for THz biophotonics, the DO model is more physically rigorous, since it satisfies the sum rule. In this way, the DO model and the sum rule were, then, applied to estimate the content of water in intact tissues and gliomas ex vivo. The observed results agreed well with the earlier-reported data, justifying water as a main endogenous label of brain tumors in the THz range. The developed models can be used to describe completely the THz-wave – human brain tissues interactions in the frameworks of classical electrodynamics, being quite important for further research and developments in THz neurodiagnosis of tumors.
  • 机译 OCT-OCTA分割:将结构和血流信息与段BRUCH膜相结合
    摘要:In this paper we present a fully automated graph-based segmentation algorithm that jointly uses optical coherence tomography (OCT) and OCT angiography (OCTA) data to segment Bruch’s membrane (BM). This is especially valuable in cases where the spatial correlation between BM, which is usually not visible on OCT scans, and the retinal pigment epithelium (RPE), which is often used as a surrogate for segmenting BM, is distorted by pathology. We validated the performance of our proposed algorithm against manual segmentation in a total of 18 eyes from healthy controls and patients with diabetic retinopathy (DR), non-exudative age-related macular degeneration (AMD) (early/intermediate AMD, nascent geographic atrophy (nGA) and drusen-associated geographic atrophy (DAGA) and geographic atrophy (GA)), and choroidal neovascularization (CNV) with a mean absolute error of ∼0.91 pixel (∼4.1 μm). This paper suggests that OCT-OCTA segmentation may be a useful framework to complement the growing usage of OCTA in ophthalmic research and clinical communities.
  • 机译 基于集成自由空间干涉仪的多光束OCT成像
    摘要:While it is a common practice to increase the speed of swept-source optical coherence tomography (OCT) systems by using a high-speed source, this approach may not always be optimal. Parallelization in the form of multiple imaging beams is an alternative approach, but scalable and low-loss multi-beam OCT architectures are needed to capitalize on its advantages. In this study, we demonstrate an eight-beam OCT system using an interferometer architecture comprising planar lightwave circuits (PLC) splitters, V-groove assemblies (VGA), and optical ribbon fibers. We achieved an excess loss and heterodyne efficiency on each channel that was close to that of single-beam systems. In vivo structural imaging of a human finger and OCT angiography imaging of a mouse ear was performed to demonstrate the imaging performance of the system. This work provides further evidence supporting multi-beam architectures as a viable strategy for increasing OCT imaging speed.
  • 机译 在光谱可见光光学相干断层扫描中的内在光谱依赖性背景
    摘要:Visible-light optical coherence tomography (vis-OCT) has enabled new spectroscopic applications, such as retinal oximetry, as a result of increased optical absorption and scattering contacts in biological tissue and improved axial resolution. Besides extracting tissue properties from back-scattered light, spectroscopic analyses must consider spectral alterations induced by image reconstruction itself. We investigated an intrinsic spectral bias in the background noise floor, which is hereby referred to as the spectrally-dependent background (SDBG). We developed an analytical model to predict the SDBG-induced bias and validated this model using numerically simulated and experimentally acquired data. We found that SDBG systemically altered the measured spectra of blood in human retinal vessels in vis-OCT, as compared to literature data. We provided solutions to quantify and compensate for SDBG in retinal oximetry. This work is particularly significant for clinical applications of vis-OCT.
  • 机译 高精度高精度3-D OCT血管造影运动校正在病理学中
    摘要:We describe a novel method for non-rigid 3-D motion correction oforthogonally raster-scanned optical coherence tomography angiographyvolumes. This is the first approach that aligns predominantly axialstructural features such as retinal layers as well as transverseangiographic vascular features in a joint optimization. Combined withorthogonal scanning and favorization of kinematically more plausibledisplacements, subpixel alignment and micrometer-scale distortioncorrection is achieved in all 3 dimensions. As no specific structuresare segmented, the method is by design robust to pathologic changes.Furthermore, the method is designed for highly parallel implementationand short runtime, allowing its integration into clinical workfloweven for high density or wide-field scans. We evaluated the algorithmwith metrics related to clinically relevant features in an extensivequantitative evaluation based on 204 volumetric scans of 17 subjects,including patients with diverse pathologies and healthy controls.Using this method, we achieve state-of-the-art axial motion correctionand show significant advances in both transverse co-alignment anddistortion correction, especially in the subgroup with pathology.
  • 机译 使用基于隐式网状蒙特卡罗算法的高度复杂组织中的光传输建模
    摘要:
  • 机译 双静脉透镜双光子内窥镜用于高速体积和深脑成像
    摘要:Studying neural connections and activities in vivo is fundamental to understanding brain functions. Given the cm-size brain and three-dimensional neural circuit dynamics, deep-tissue, high-speed volumetric imaging is highly desirable for brain study. With sub-micrometer spatial resolution, intrinsic optical sectioning, and deep-tissue penetration capability, two-photon microscopy (2PM) has found a niche in neuroscience. However, the current 2PM typically relies on a slow axial scan for volumetric imaging, and the maximal penetration depth is only about 1 mm. Here, we demonstrate that by integrating a gradient-index (GRIN) lens and a tunable acoustic GRIN (TAG) lens into 2PM, both penetration depth and volume-imaging rate can be significantly improved. Specifically, an ∼ 1-cm long GRIN lens allows imaging relay from any target region of a mouse brain, while a TAG lens provides a sub-second volume rate via a 100 kHz ∼ 1 MHz axial scan. This technique enables the study of calcium dynamics in cm-deep brain regions with sub-cellular and sub-second spatiotemporal resolution, paving the way for interrogating deep-brain functional connectome.
  • 机译 高光谱显微镜与DAPI染色联合用于鉴定肝癌细胞
    摘要:In this study, the DAPI staining is firstly reported for use in the identification of hepatic carcinoma cells based on hyperspectral microscopy. Nuclei in cancer cells usually contain more aneuploidies than that in normal cells, leading to the change of DNA content. Here, we stain hepatic carcinoma tissues and normal hepatic tissues with 4’,6-diamidino-2-phenylindole (DAPI) which is sensitive to the DNA content as a fluorochrome binds to DNA. Consequently, the difference in DNA content between hepatic carcinoma cells and normal hepatic cells can be identified by the fluorescent spectral characteristics. Harnessing the hyperspectral microscopy, we find that the fluorescent properties of these two kinds of cells are different not only in the intensity but also in the spectral shape. These properties are exploited to train a support vector machine (SVM) model for classifying cells. The results show that the sensitivity and specificity for the identification of 1000 hepatic carcinoma samples are 99.3% and 99.1%, respectively.
  • 机译 等级指数光纤提示使芯片吸收光谱有限
    摘要:This paper describes the design and characterization of miniaturized optofluidic devices for sensing based on integrating collimating optical fibers with custom microfluidic chips. The use of collimating graded-index fiber (GIF) tips allows for effective fiber-channel-fiber interfaces to be realized when compared with using highly-divergent standard single-mode fiber (SMF). The reduction in both beam divergence and insertion losses for the GIF configuration compared with SMF was characterized for a 10.0 mm channel. Absorption spectroscopy was demonstrated on chip for the measurement of red color dye (Ponceau 4R), and the detection of thiocyanate in water and artificial human saliva. The proposed optofluidic setup allows for absorption spectroscopy measurements to be performed with only 200 µL of solution which is an order of magnitude smaller than for standard cuvettes but provides a comparable sensitivity. The approach could be integrated into a lab-on-a-chip system that is compact and does not require free-space optics to perform absorption spectroscopy.
  • 机译 使用深度学习的地面真理缺陷的基于真理的缺陷的纳米检查图像中的人工制品
    摘要:Image denoising or artefact removal using deep learning is possible in the availability of supervised training dataset acquired in real experiments or synthesized using known noise models. Neither of the conditions can be fulfilled for nanoscopy (super-resolution optical microscopy) images that are generated from microscopy videos through statistical analysis techniques. Due to several physical constraints, a supervised dataset cannot be measured. Further, the non-linear spatio-temporal mixing of data and valuable statistics of fluctuations from fluorescent molecules that compete with noise statistics. Therefore, noise or artefact models in nanoscopy images cannot be explicitly learned. Here, we propose a robust and versatile simulation-supervised training approach of deep learning auto-encoder architectures for the highly challenging nanoscopy images of sub-cellular structures inside biological samples. We show the proof of concept for one nanoscopy method and investigate the scope of generalizability across structures, and nanoscopy algorithms not included during simulation-supervised training. We also investigate a variety of loss functions and learning models and discuss the limitation of existing performance metrics for nanoscopy images. We generate valuable insights for this highly challenging and unsolved problem in nanoscopy, and set the foundation for the application of deep learning problems in nanoscopy for life sciences.
  • 机译 成像分辨率对穆勒矩阵衍生线性延迟参数的对比研究
    摘要:Polarization imaging techniques are emerging tools to provide quantitative information of anisotropic structures, such as the density and orientation distribution of fibers in tissue samples. Recently, it is found that when using Mueller matrix polarimetry to obtain the structural features of tissue samples, some information can be revealed by relatively low-resolution polarization parameter images. Thus, to analyze what kinds of anisotropic optical and structural information contained in high-resolution polarization images are preserved in low-resolution ones, here we carry out a comparative study of the influence of imaging resolution on the Mueller matrix derived linear retardance parameters. We measure the microscopic Mueller matrix of human healthy breast duct tissues and ductal carcinoma in situ (DCIS) tissues, which have distinct typical fibrous structures, using objectives with different numerical aperture. Then we quantitatively compare a group of image texture feature parameters of the linear retardance parameters images under high and low imaging resolutions. The results demonstrate that the fibers density information contained in the texture features of linear retardance δ parameter image are preserved well with the decline of imaging resolution. While for the azimuthal orientation parameter θ which closely related to the spatial location, we still need high imaging resolution to obtain quantitative structural information. The study provides an important criterion to decide which information of fibrous structures can be extracted accurately using transmission Mueller matrix microscope with low numerical aperture objectives.
  • 机译 校正高速导管/内窥镜基光相干断层扫描中的圆周和纵向运动变形
    摘要:Catheter/endoscope-based optical coherence tomography (OCT) is a powerful modality that visualizes structural information in luminal organs. Increases in OCT speed have reduced motion artifacts by enabling acquisition faster than or comparable to the time scales of physiological motion. However motion distortion remains a challenge because catheter/endoscope OCT imaging involves both circumferential and longitudinal scanning of tissue. This paper presents a novel image processing method to estimate and correct motion distortion in both the circumferential and longitudinal directions using a single en face image from a volumetric data set. The circumferential motion distortion is estimated and corrected using the en face image. Then longitudinal motion distortion is estimated and corrected using diversity of image features along the catheter pullback direction. Finally, the OCT volume is resampled and motion corrected. Results are presented on synthetic images and clinical OCT images of the human esophagus.
  • 机译 激励扫描高光谱视频内窥镜:增强隧道末端的光
    摘要:Colorectal cancer is the 3rd leading cancer for incidence and mortality rates. Positive treatment outcomes have been associated with early detection; however, early stage lesions have limited contrast to surrounding mucosa. A potential technology to enhance early stagise detection is hyperspectral imaging (HSI). While HSI technologies have been previously utilized to detect colorectal cancer ex vivo or post-operation, they have been difficult to employ in real-time endoscopy scenarios. Here, we describe an LED-based multifurcated light guide and spectral light source that can provide illumination for spectral imaging at frame rates necessary for video-rate endoscopy. We also present an updated light source optical ray-tracing model that resulted in further optimization and provided a ∼10X light transmission increase compared to the initial prototype. Future work will iterate simulation and benchtop testing of the hyperspectral endoscopic system to achieve the goal of video-rate spectral endoscopy.
  • 机译 检测实验角膜升瓣光动力抗菌治疗的单线氧发光
    摘要:Rose bengal photodynamic antimicrobial therapy (RB-PDAT) treats corneal infection by activating rose bengal (RB) with green light to produce singlet oxygen (1O2). Singlet oxygen dosimetry can help optimize treatment parameters. We present a 1O2 dosimeter for detection of 1O2 generated during experimental RB-PDAT. The system uses a 520 nm laser and an InGaAs photoreceiver with bandpass filters to detect 1O2 luminescence during irradiation. The system was validated in RB solutions and ex vivo in human donor eyes. The results demonstrate the feasibility of 1O2 dosimetry in an experimental model of RB-PDAT in the cornea.
  • 机译 多光子成像的杂散光和背景动态实时减法
    摘要:We introduce a new approach to reduce uncorrelated background signals from fluorescence imaging data, using real-time subtraction of background light. This approach takes advantage of the short fluorescence lifetime of most popular fluorescent activity reporters, and the low duty-cycle of ultrafast lasers. By synchronizing excitation and recording, laser-induced multiphoton fluorescence can be discriminated from background light levels with each laser pulse. We demonstrate the ability of our method to – in real-time – remove image artifacts that in a conventional imaging setup lead to clipping of the signal. In other words, our method enables imaging under conditions that in a conventional setup would yield corrupted data from which no accurate information can be extracted. This is advantageous in experimental setups requiring additional light sources for applications such as optogenetic stimulation.
  • 机译 具有振动红外光热和相位信号的成纤维细胞膜界面和蛋白质签名的无标记成像
    摘要:Label-free vibrational imaging of biological samples has attracted significant interest due to its integration of structural and chemical information. Vibrational infrared photothermal amplitude and phase signal (VIPPS) imaging provide label-free chemical identification by targeting the characteristic resonances of biological compounds that are present in the mid-infrared fingerprint region (3 µm - 12 µm). High contrast imaging of subcellular features and chemical identification of protein secondary structures in unlabeled and labeled fibroblast cells embedded in a collagen-rich extracellular matrix is demonstrated by combining contrast from absorption signatures (amplitude signals) with sensitive detection of different heat properties (lock-in phase signals). We present that the detectability of nano-sized cell membranes is enhanced to well below the optical diffraction limit since the membranes are found to act as thermal barriers. VIPPS offers a novel combination of chemical imaging and thermal diffusion characterization that paves the way towards label-free imaging of cell models and tissues as well as the study of intracellular heat dynamics.

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号