In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population

机译:角膜可视化Scheimpflug技术在中国人群体内的角膜生物力学特性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose. To determine the repeatability of recalculated corneal visualization Scheimpflug technology (CorVis ST) parameters and to study the variation of biomechanical properties and their association with demographic and ocular characteristics. Methods. A total of 783 healthy subjects were included in this study. Comprehensive ophthalmological examinations were conducted. The repeatability of the recalculated biomechanical parameters with 90 subjects was assessed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Univariate and multivariate linear regression models were used to identify demographic and ocular factors. Results. The repeatability of the central corneal thickness (CCT), deformation amplitude (DA), and first/second applanation time (A1/A2-time) exhibited excellent repeatability (CV% ≤ 3.312% and ICC ≥ 0.929 for all measurements). The velocity in/out (V in/out), highest concavity- (HC-) radius, peak distance (PD), and DA showed a normal distribution. Univariate linear regression showed a statistically significant correlation between V in, V out, DA, PD, and HC-radius and IOP, CCT, and corneal volume, respectively. Multivariate analysis showed that IOP and CCT were negatively correlated with V in, DA, and PD, while there was a positive correlation between V out and HC-radius. Conclusion. The ICCs of the recalculated parameters, CCT, DA, A1-time, and A2-time, exhibited excellent repeatability. IOP, CCT, and corneal volume significantly influenced the biomechanical properties of the eye.
机译:目的。为了确定重新计算的角膜可视化Scheimpflug技术(CorVis ST)参数的可重复性,并研究生物力学特性的变化及其与人口统计和眼部特征的关系。方法。本研究共纳入783名健康受试者。进行了全面的眼科检查。通过变异系数(CV)和组内相关系数(ICC)评估了90位受试者重新计算的生物力学参数的可重复性。使用单变量和多元线性回归模型来确定人口统计学和眼科因素。结果。中心角膜厚度(CCT),变形幅度(DA)和第一/第二压平时间(A1 / A2时间)的可重复性表现出极好的可重复性(所有测量的CV%≤3.312%和ICC≥0.929)。速度输入/输出(V输入/输出),最大凹度(HC-)半径,峰距(PD)和DA显示正态分布。单变量线性回归显示V in,V out,DA,PD和HC半径与IOP,CCT和角膜体积之间的统计学显着相关性。多因素分析表明,眼压和CCT与V in,DA和PD呈负相关,而V out与HC半径呈正相关。结论。重新计算的参数的ICC(CCT,DA,A1时间和A2时间)具有极好的可重复性。 IOP,CCT和角膜体积显着影响眼睛的生物力学性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号